4. PARAMETERS
No./symbol/
Setting
name
digit
PC75
Set the output level of the following error output.
FEWL
Upper and lower are a set.
Following
As the droop pulses condition exceeds the value of [Pr. PC75, Pr. PC76],
error output
when the time set in [Pr. PC77] has elapsed, the "Statusword (Index:
level
6041h) bit 13 Following error" is turned on. However, setting
"FFFFFFFFh" disables it.
(Lower four
digits)
Set the value in hexadecimal.
Setting value:
The unit can be changed to 10
setting of [Pr. PT01].
This parameter corresponds to "Following error window (Index: 6065h)".
When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 00000000h to FFFFFFFFh
PC76
Set the output level of the following error output.
FEWH
Upper and lower are a set.
Following
Refer to [Pr. PC75] for details.
error output
The unit can be changed to 10
level
setting of [Pr. PT01].
(Upper four
digits)
PC77
Set the time until the following error output is turned on.
FEWF
As the droop pulses condition exceeds the value of [Pr. PC75, Pr. PC76],
when the time set by this parameter has elapsed, the "Statusword (Index:
Following
6041h) bit 13 Following error" is turned on.
error output
filtering time
The following error output is disabled when both [Pr. PC75] and [Pr.
PC76] are "FFFFh".
This parameter corresponds to "Following error time out (Index: 6066h)".
When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 0 to 65535
Function
Upper four
Lower four
digits
digits
[Pr. PC75]
[Pr. PC76]
STM
[μm], 10
(STM-4)
STM
[μm], 10
(STM-4)
4 - 23
Initial
value
[unit]
0000h
Refer to
Function
column
for unit.
[inch], or [pulse] with the
0000h
Refer to
Function
column
[inch], or [pulse] with the
for unit.
0000h
Refer to
Function
column
for unit.
General
Communication
purpose
CP
PS
CP
PS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents