4. PARAMETERS
No./symbol/
Setting
name
digit
PT17
Set an address decreasing side of the software stroke limit.
LMNL
Upper and lower are a set.
Software limit
Set an address in hexadecimal.
-
(Lower four
Setting address:
digits)
The stop method follows the "Stopping method at software limit detection"
of [Pr. PD35]. The initial value is "slow stop".
Setting the same value in "Software limit +" will disable the software
stroke limit. (Refer to section 4.3.)
PT18
To change the setting of this parameter, change with the servo-off or with
LMNH
the home return mode.
Software limit
When changing the setting of the positioning mode during servo on,
-
changing the setting in a certain order triggers [AL. 35], [AL. 69], or [AL.
(Upper four
98].
digits)
The unit can be changed to 10
setting of [Pr. PT01].
This parameter corresponds to "Min position limit (Index: 607Dh, Sub:
1)". When this parameter is mapped to the link device of CC-Link IE Field
Network Basic, do not write the parameter value with MR Configurator2,
as the controller overwrites the parameter value written with MR
Configurator2.
Setting range: 00000000h to FFFFFFFFh
PT19
Set an address increasing side of the position range output address.
Upper and lower are a set.
*LPPL
Set a range in which POT (Position range) turns on with [Pr. PT19] to [Pr.
Position
PT22].
range output
address +
Set an address in hexadecimal.
(Lower four
digits)
Setting address:
PT20
*LPPH
Position
range output
address +
The unit can be changed to 10
(Upper four
setting of [Pr. PT01].
digits)
Setting range: 00000000h to FFFFFFFFh
Function
Upper four
Lower four
digits
digits
[Pr. PT17]
[Pr. PT18]
[μm], 10
STM
(STM-4)
Upper four
Lower four
digits
digits
[Pr. PT19]
[Pr. PT20]
STM
[μm], 10
(STM-4)
4 - 35
Initial
value
[unit]
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.
[inch], or [pulse] with the
0000h
Refer to
Function
column
for unit.
0000h
Refer to
Function
column
for unit.
[inch], or [pulse] with the
General
Communication
purpose
CP
PS
CP
PS

Hide quick links:

Advertisement

Table of Contents
loading