12. WHEN USING WITH A GENERAL-PURPOSE INTERFACE
5) Temporary stop/restart
When TSTP (Temporary stop/restart) is switched on during automatic operation, the servo motor
decelerates with the deceleration time constant of the point table being executed, and then stops
temporarily.
Switching on TSTP (Temporary stop/restart) again starts the servo motor rotation for the
remaining travel distance.
During a temporary stop, ST1 (Forward rotation start) or ST2 (Reverse rotation start) does not
function even if switched on.
When any of the following conditions is satisfied during a temporary stop, the travel remaining
distance is cleared.
The automatic operation mode is switched to the manual operation mode or homing mode.
The servo amplifier enters the servo-off status.
The clear signal is inputted.
The temporary stop/restart input functions in the following status.
Operation status
During a stop
During acceleration
At a constant speed
During deceleration
During a temporary
stop
a) When the servo motor is rotating
Servo motor speed
Point table
ST1 (Forward rotation start)
or ST2 (Reverse rotation start)
TSTP (Temporary stop/restart)
PUS (Temporary stop)
CPO (Rough match)
INP (In-position)
MEND (Travel completion)
PT0 (Point table No. output 1)
to PT7 (Point table No. output 8)
(Note)
Note. Up to four points of DO are available; therefore, PT0 to PT7 cannot be outputted simultaneously.
Automatic operation
Temporary stop
Temporary stop
Restart
Acceleration time constant
of point table No. n
Forward rotation
0 r/min
Reverse rotation
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
12 - 64
Deceleration time constant
of point table No. n
Remaining
distance
No. n
No. n