7. HOW TO USE THE POINT TABLE
(b) Parameter setting
Set the following parameters to perform automatic operation.
1) Command method selection ([Pr. PT01])
Select the absolute value command method as shown below.
[Pr. PT01]
2) Rotation direction selection ([Pr. PA14])
Select the servo motor rotation direction when "Controlword bit 4 (New set-point)" is switched on.
[Pr. PA14] setting
0
1
CCW
CW
3) Position data unit ([Pr. PT01])
Set the unit of the position data.
[Pr. PT01] setting
_ 0 _ _
_ 1 _ _
_ 3 _ _
4) Feed length multiplication ([Pr. PT03])
Set the feed length multiplication factor (STM) of the position data.
[Pr. PT03] setting
_ _ _ 0
_ _ _ 1
_ _ _ 2
_ _ _ 3
Note 1. The "-" sign has different meanings under the absolute value command method and the incremental value
command method. Refer to section 7.2.1 for details.
2. The feed length multiplication setting ([Pr. PT03]) is not applied to the unit multiplication factor.
Adjust the unit multiplication factor in the electronic gear setting ([Pr. PA06] and [Pr. PA07]).
0
Absolute value command method
Servo motor rotation direction
"Controlword bit 4 (New set-point)" on
CCW rotation with + position data
CW rotation with - position data
CW rotation with + position data
CCW rotation with - position data
Position data unit
mm
inch
pulse
[mm]
- 999.999 to + 999.999
- 9999.99 to + 9999.99
- 99999.9 to + 99999.9
- 999999 to + 999999
Position data input range (Note 1)
[inch]
- 99.9999 to + 99.9999
- 999.999 to + 999.999
- 9999.99 to + 9999.99
- 99999.9 to + 99999.9
7 - 8
[pulse] (Note 2)
- 999999 to + 999999

Hide quick links: