P1 - 03
AOUT

Pulse Output Polarity Setting

Default: 0
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 3
Data Size: 16-bit
Display Format: HEX
Settings:
P1 - 04
MON1

Analog Monitor Output Proportion 1(CH1)

Default: 100
Applicable Control Mode: ALL
Unit: % (full scale)
Range: 0 ~ 100
Data Size: 16-bit
Display Format: DEC
P1 - 05
MON2

Analog Monitor Output Proportion 2(CH2)

Default: 100
Applicable Control Mode: ALL
Unit: % (full scale)
Range: 0~100
Data Size: 16-bit
Display Format: DEC
Revision June 2010
Monitor analog output polarity
• A=0: MON1(+), MON2(+)
• A=1: MON1(+), MON2(-)
A
• A=2: MON1(-), MON2(+)
B
• A=3: MON1(-), MON2(-)
not used
Pulse output polarity
• B=0: Forward output
• B=1: Reverse output
Chapter 6 Control Modes of Operation
Communication Addr.:
0106H, 0107H
Related Section:
Section 3.3.3
Communication Addr.:
0108H, 0109H
Related Section:
Section 6.4.4
Communication Addr.:
0108H, 0109H
Related Section:
Section 6.4.4
6-39