Display Format: Decimal
Settings:
This parameter is used to set magnitude of the resonance suppression that is set
by parameter P2-43. If P2-44 is set to 0, the parameters P2-43 and P2-44 are both
disabled.
P2 - 45
NCF3
Default: 1000
Applicable Control Mode: ALL
Unit: Hz
Range: 50 ~ 2000
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set third resonance frequency of mechanical system. It
can be used to suppress the resonance of mechanical system and reduce the
vibration of mechanical system.
If P2-45 is set to 0, this parameter is disabled.
P2 - 46
DPH3
Default: 0
Applicable Control Mode: ALL
Unit: dB
Range: 0 ~ 32
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set magnitude of the resonance suppression that is set
by parameter P2-45. If P2-46 is set to 0, the parameters P2-45 and P2-46 are both
disabled.
P2 - 47
ANCF
Default: 1
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 2
Data Size: 16-bit
Display Format: Decimal
Revision June 2010
Notch Filter 3 (Resonance Suppression)
Notch Filter Attenuation Rate 3
(Resonance Suppression)
Auto Resonance Suppression Mode
Selection
Chapter 7 Servo Parameters
Address: 025AH, 025BH
Related Section:
Section 6.3.7
Address: 025CH, 025DH
Related Section:
Section 6.3.7
Address: 025EH, 025FH
Related Section: N/A
7-59