Chapter 7 Servo Parameters
Table 7.B Output Function Definition
Setting value: 0x01
DO Name
Servo ready. SRDY is activated when the servo drive is
SRDY
ready to run. All fault and alarm conditions, if
present, have been cleared.
Setting value: 0x02
DO Name
SON is activated when control power is applied the
servo drive. The drive may or may not be ready to run
as a fault / alarm condition may exist.
Servo ON (SON) is "ON" with control power applied to
SON
the servo drive, there may be a fault condition or not.
The servo is not ready to run. Servo ready (SRDY) is
"ON" where the servo is ready to run, NO fault / alarm
exists.
Setting value: 0x03
DO Name
ZSPD is activated when the drive senses the motor is
equal to or below the Zero Speed Range setting as
defined in parameter P1-38.
ZSPD
For Example, at factory default ZSPD will be activated
when the drive detects the motor rotating at speed at
or below 10 r/min, ZSPD will remain activated until
the motor speed increases above 10 r/min.
7-90
DO Function Description