P1 - 05
MON2
Default: 100
Applicable Control Mode: ALL
Unit: % (full scale)
Range: 0 ~ 100
Data Size: 16-bit
Display Format: Decimal
P1 - 06
SFLT
Default: 0
Applicable Control Mode: S
Unit: msec
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display Format: Decimal
P1 - 07
TFLT
Default: 0
Applicable Control Mode: T
Unit: msec
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display Format: Decimal
P1 - 08
PFLT
Default: 0
Applicable Control Mode: PT
Unit: 10msec
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display Format: Decimal
Revision June 2010
Analog Monitor Output Proportion 2
(CH2)
Accel / Decel Smooth Constant of Analog
Speed Command (Low-pass Filter)
Smooth Constant of Analog Torque
Command (Low-pass Filter)
Smooth Constant of Position Command
(Low-pass Filter)
Chapter 7 Servo Parameters
Address: 010AH, 010BH
Related Section:
Section 6.4.4
Address: 010CH, 010DH
Related Section:
Section 6.3.3
Address: 010EH, 010FH
Related Section:
Section 6.4.3
Address: 0110H, 0111H
Related Section:
Section 6.2.6
7-25