Chapter 11 Specifications
Model: ASD-B2 Series
Voltage Range
Analog Input
Command
Time Constant
Command Source
Smoothing Strategy
Speed Limit Operation
Analog Monitor Output
Digital
Inputs/Outputs
Protective Functions
Communication Interface
Installation Site
Altitude
Atmospheric pressure
Operating Temperature
Storage Temperature
Humidity
Vibration
IP Rating
Power System
Standards/Requirement
11-2
100W
200W
01
Input
Resistance
Monitor signal can set by parameters (Output voltage range: ±8V)
Servo On, Reset, Gain switching, Pulse clear, Zero speed CLAMP,
Command input reverse control, Speed/Torque limit enabled,
Speed command selection, Position / Speed mode switching, Speed
Inputs
/ Torque mode switching, Torque / Position mode switching,
Emergency stop, Forward / Reverse inhibit limit, Forward / Reverse
operation torque limit, Forward / Reverse JOG input, Electronic gear
ratio (Numerator) selection and Pulse inhibit input
Encoder signal output (A, B, Z Line Driver / Z Open collector)
Servo ready, Servo On, At Zero speed, At Speed reached, At
Outputs
Positioning completed, At Torques limit, Servo alarm (Servo fault)
activated, Electromagnetic brake control, Output overload warning,
Servo warning activated
Overcurrent, Overvoltage, Undervoltage, Motor overheated,
Overload, Overspeed, Excessive deviation, Regeneration error,
Abnormal pulse control command, Encoder error, Adjustment
error, Emergency stop activated, Reverse/ Forward limit switch
error, IGBT temperature error, Serial communication error, Input
power phase loss, Serial communication time out, terminals with
short circuit protection (U, V ,W , CN1, CN2, CN3 terminals)
Indoor location (free from direct sunlight), no corrosive liquid and
gas (far away from oil mist, flammable gas, dust)
o
0
C to 55
9.80665m/s
400W
750W
02
04
07
0 ~ ±10 V
External analog signal / Internal parameters
Low-pass filter
Parameter Setting or via Analog input
RS-232/RS-485
Altitude 1000m or lower above sea level
86kPa to 106kPa
o
C (32°F to 131°F) (If operating temperature is above
specified range, forced cooling will be required)
-20℃ ~ 65℃
0 to 90% (non-condensing)
2
(1G) less than 20Hz, 5.88m/ s
TN System
IEC/EN 61800-5-1, UL 508C
1kW
1.5kW
10
15
DC
10KΩ
2.2 us
2
(0.6G) 20 to 50Hz
IP20
*4
Revision June 2010
2kW
3kW
20
30