MX960 3D Universal Edge Router Hardware Guide
254
NOTE:
The XFP cages and optics on the components are industry standard
parts that have limited tactile feedback for insertion of optics and fiber.
You need to insert the optics and fiber firmly until the latch is securely in
place.
Arrange the cable to prevent it from dislodging or developing stress points. Secure
4.
the cable so that it is not supporting its own weight as it hangs to the floor. Place
excess cable out of the way in a neatly coiled loop.
CAUTION:
Avoid bending fiber-optic cable beyond its minimum bend
radius. An arc smaller than a few inches in diameter can damage the cable
and cause problems that are difficult to diagnose.
CAUTION:
Do not let fiber-optic cable hang free from the connector. Do
not allow fastened loops of cable to dangle, which stresses the cable at
the fastening point.
Figure 87: Attaching a Cable to a DPC
Figure 88: Attaching a Cable to a MIC
Fiber-optic cable
Fiber-optic cable
connector