MX960 3D Universal Edge Router Hardware Guide

Table 74: AC Power System Specifications

Item
Normal-Capacity
Redundancy
3+1
Output power (maximum)
1700 W
per supply
Output power (maximum)
5100 W
per system
Related
Documentation

Power Requirements for an MX960 Router

152
Table 73: AC Power Supply Electrical Specifications (continued)
Item
Specification
AC input line frequency
50 to 60 Hz
AC input current rating
Two-feed mode
26 A (13 A per feed)
Maximum AC inrush current
76 A (38 A per feed at 264 VAC)
Efficiency
~88%
NOTE:
This value is at full
load and nominal voltage.
MX960 AC Power Supply Description on page 98
Replacing an MX960 AC Power Supply on page 391
Installing an MX960 AC Power Supply on page 290
show chassis power
Table 75 on page 153
lists the MX960 base system and cooling system power requirements.
Table 76 on page 153
lists the FRU power requirements for Switch Control Boards (SCBs),
Routing Engines, Modular Port Concentrators (MPCs), Modular Interface Cards (MICs),
Dense Port Concentrators (DPCs), and PICs. In addition,
MPC power requirements with MICs and optics at various operating temperatures.
Typical power represents power under certain temperatures and normal operating
conditions.
High-Capacity
All PEMs in two-feed
mode
All PEMs in one-feed mode
2+2
2+2
4100 W
1700 W
8200 W
3400 W
Table 76 on page 153
Copyright © 2017, Juniper Networks, Inc.
One-feed mode
13 A
38 A per feed at 264 VAC