To connect the alarm relay wires between a router and an alarm-reporting device (see
Figure 89 on page
255):
Prepare the required length of replacement wire with gauge between 28-AWG and
1.
14-AWG (0.08 and 2.08 mm
Insert the replacement wires into the slots in the front of the block. Use a 2.5-mm
2.
flat-blade screwdriver to tighten the screws and secure the wire.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
3.
ESD points on the chassis.
Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver
4.
to tighten the screws on the face of the block.
Attach the other end of the wires to the external device.
5.
Figure 89: Alarm Relay Contacts
Preventing Electrostatic Discharge Damage to an MX960 Router
Disconnecting the Alarm Relay Wires from the MX960 Craft Interface on page 307