Configuring Recurring Daylight Savings Time - Avaya 4524GT Configuration Manual

Ethernet routing switch 4500 series
Table of Contents

Advertisement

set daylight savings time example
clock summer-time BST date 28 Mar 2007 2:00 30 Aug 2007 15:00 +60
This command sets the daylight savings time to begin at 02:00 on March 28, 2007 and end on
August 30th, 2007 at 15:00. The change to daylight savings moves the clock forward by 60
minutes and "BST" will be displayed as the time zone acronym. These changes to and from
daylight savings time will happen automatically.

Configuring recurring daylight savings time

Use this procedure to configure the daylight saving time start and end times for a single
occurrence or to recur annually.
1. In ACLI, set the global configuration mode.
2. Enable the SNTP server.
3. Set the date to change to daylight savings time.
Configuration — System
Variables
date
day
month
year
hh:mm
day
month
year
hh:mm
offset
zone
clock summer-time recurring (<startWeek:1-5>|last}
<start:DAY> <start:MONTH> <start:hh:mm> {<endWeek:1-5>|last}
<endDAY> <end:MONTH> <end:hh:mm> [offset <1-1440>]
General switch administration using ACLI
Description
Indicates that daylight savings time you
set to start and end on the specified
days every year.
Date to start daylight savings time.
Month to start daylight savings time.
Year to start daylight savings time.
Hour and minute to start daylight
savings time.
Date to end daylight savings time.
Month to end daylight savings time.
Year to end daylight savings time.
Hour and minute to end daylight
savings time.
Number of minutes to add during the
summer time.
The time zone acronym to be displayed
when daylight savings time is in effect.
If it is unspecified, it defaults to the time
zone acronym set when the time zone
was set.