System configuration using Enterprise Device Manager
Variable
Notification
ControlEnable
PowerDevice
DetectType
PowerPresent

Configuring system parameters using EDM

Use this procedure to view and modify the system level configuration.
Procedure steps
1. From the Configuration navigation tree, click the Edit arrowhead to open the Edit
2. Double-click Chassis .
3. In the Chassis tree, double-click Chassis.
4. In the work area, click the System tab.
5. In the sysContact field, type system contact information.
220
Configuration — System
Important:
You must enable the traps (NotificationControlEnable) to receive a
power usage trap.
Enables (true) or disables (false) the sending of traps if the switch power
usage exceeds the configured threshold percentage.
Specifies the power detection type that the switch uses to detect a
request for power from a device connected to all ports on the switch.
Values include:
• 802.3af
• 802.3af and legacy
Important:
The default setting is 802.3af. Ensure that this setting matches the
setting for the detection type used by the powered devices on this
switch.
Indicates the currently used power source. Available power sources are
AC and DC.
• acOnly—indicates that the only power supply is AC
• dcOnly—indicates that the only power supply is DC
• acDc—indicates that there are two power supplies; both AC and DC
are supplying power
This is a read-only cell.
navigation tree.