Fuse Block

To access the fuses, you must remove the heat shield.
1. Stop the engine and remove the key.
2. Raise the hood.
3. Pull the hairpin cotter from the bottom end of the
hood prop rod and slide the prop rod out of the
retaining brackets and the prop rod tab.
4. Remove the 4 screws securing the heat shield and
then pull the shield out and up to remove it.
5. Check the fuses. Replace as necessary (Fig. 0069).
Note: Fuses can be removed to check continuity.
The test meter should read less than 1 ohm.
D
C
A. 30 amp = Main circuit
B. Empty
C. 10 amp = Control panel / Relay
D. Open position for optional accessories
TX525 Service Manual
B
A
Fig 0069
PICT-8753
MAINTENANCE
6. Install the heat shield using the 4 screws removed
previously.
7. Install the prop rod into the retaining brackets and
prop rod tab and secure it with the hairpin cotter.
8. Close the hood.

Hydrostatic Pump Belt

Every 25 hours inspect the drive belt for wear or
damage.
Replace the belt if you find any signs of wear, cracks, or
damage or yearly, whichever comes first (Fig. 0070).
Rev. 000
Fig 0070
PICT-8756