40. Remove the right hand hydrostatic pump from the
tower frame (Fig. 1368).
41. If replacing the pump, transfer all markings and
fittings to the new pump (Fig. 1369).
Note: Do not install the fittings marked D and E.
42. If repairing/rebuilding the pump, refer to the Hydro-
Gear BDP-10A/16A/21L Hydrostatic Pumps Service
and Repair Manual (Toro Form No. 492-4789).
TX525 Service Manual
Fig 1368
PICT-4753
Fig 1369
PICT-4754a
DRIVE SYSTEM

Right Hydrostatic Pump Installation

1. With the lower pump mounting bolt and nut loosely
installed in the tower frame, position the right hand
hydrostatic pump so the pump shaft is inserted
through the frame (Fig. 1370).
2. Using a 3/4" socket and wrench, install the top bolt
and nut. Tighten the lower bolt and nut securing the
right hand hydrostatic pump to the tower frame (Fig.
1371).
Rev. 000
Fig 1370
PICT-4753
Fig 1371
PICT-8900