Auxiliary Valve Rebuild; Auxiliary Valve - Toro TX525 Service Manual

Hide thumbs Also See for TX525:
Table of Contents

Advertisement

Auxiliary Valve Rebuild

Note: Cleanliness is a key factor in a successful
repair of any valve system. Thoroughly clean
all exposed surfaces prior to any type of
maintenance. Cleaning all parts by using
a solvent wash and air drying is usually
adequate. As with any precision equipment,
all parts must be kept free of foreign material
and chemicals. Protect all exposed sealing
areas and open cavities from damage and
foreign material.
Upon removal, all seals, o-rings, and gaskets
should be replaced. During installation, lightly
lubricate all seals, o-rings, and gaskets with
clean petroleum jelly prior to assembly.
Protect the inner diameter of seals and
o-rings from damage during assembly by
covering the shaft machined features with
plastic wrap or equivalent.

Auxiliary Valve

H
G
F
A. Operator lever
B. Inlet
C. Safety switch port
D. Detent cap
TX525 Service Manual
A
B
C
D
E
Fig 1045
PICT-2674a
E. Return spring cap
F. Relief
G. Return
H. Directional ports
HYDRAULIC SYSTEM
1. Using a 7/8" wrench, remove the safety switch from
the valve (Fig. 1046).
2. Using a 4mm Allen wrench, loosen the two screws
securing the return spring cap to the valve (Fig.
1047).
Rev. 000
Fig 1046
PICT-2677a
Fig 1047
PICT-2678a