Testing
Disconnect the two wires and remove the mounting
screws. Remove the sender from the fuel tank. Place
the VOM negative lead on the negative terminal and the
positive lead on the center stud. Refer to the chart below
for proper resistance depending on float position.
Float Position
Full
Empty
Alarm, Low Engine Oil
Purpose
The audible alarm produces a pulsating loud tone to
alert the operator of high engine temperature.
Location
The audio alarm is located in the control panel under the
left control panel cover (Fig. 0821).
TX525 Service Manual
Resistance
33 ohms + 20 ohms
240 ohms + 6 ohms
Fig 0821
IMG-6937
How It Works
There is +12VDC applied to the audio alarm when the
key is in the ON or RUN positions. The Water Temper-
ature Light provides a ground for the light and the audio
alarm.
Testing
Ground the negative terminal (-) on the alarm. Apply
12 volts to the positive terminal (+) on the alarm. If the
alarm does not sound, replace the alarm. If the alarm
does sound test the electrical circuit (Fig. 0822).
Rev. 000
ELECTRICAL
Fig 0822
IMG-6969a
5-13