Disconnect timeout after and external-
to-external transfer
With this option you can specify a period of time for dis-
connecting an external call. This option applies when at
least one external line is an analog line and the call is
transferred (Code 091) or forwarded (*11) to an external
destination by an authorized extension.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
efd
Enter the length of time for disconnecting calls (004 to
120 in 5-second cycles) where 004 = 20 seconds ...
060 = 300 seconds (default), etc.
w
Initial status for programming mode.
Code to disconnect timeout after
external-to-external transfer
This option allows you to set a code to restart the time-
out period for disconnecting an external call. This ap-
plies when at least one external line is an analog line,
and after a call has been transferred (Code 091) or for-
warded (*11) to an external destination by an authorized
extension.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
w
p
Enter a code for restarting the timeout, between 00 and
99 (default is 00).
w
Initial status for programming mode.
Once the call is transferred and answered at the
destination, a disconnect timer is activated (de-
fault is 5 minutes).
A 20-second warning tone is sent to both parties
before the call is disconnected. In order to con-
tinue the call without disconnecting, the destina-
tion number must enter this code (MF , default
"00") to restart the timeout.,