Siemens HiPath 1100 Programming Manual page 229

Analog mf telephones
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

2
Model S30817-Q936-C282
2.1 Settings
J1
ON: Works as a pager
OFF: Works as an entrance telephone.
J2
ON: Deactivates the timeout for paging.
OFF: Activates a 15-second timeout for paging.
J3 to J8
Not used
Aspects to Consider
The length of the cables between the X2 connector and the PABX must
not exceed 32.8 feet.
For information on the length of wiring between the X6 connector and
the entrance telephone (at the street) see the manufacturer's specifi-
cations. This interface supports HDL 's brand entrance telephones
(F5AZ, F8AZ and F9AZ).
In Pager Mode the X4 connector is connected to an audio output, and
the X5 connector to an audio input.
For more details see the Service Manual.
Setup and Installation
229

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 1120Hipath 1150Hipath 1190

Table of Contents