External line settings
Step by step
efm
di
...
46
w
p
Enter the next number for the analog trunk.
or
w
r
Press this key.
Initial status for programming mode.

Reseizure timeout for an external line

There is a timeout for reseizing an external line. Once an
outgoing call has ended the line will remain blocked dur-
ing the specified timeout.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
w
mm
Enter the length of time (05 to 99) for the Flash signal,
where 05 = 500 ms (default) to 99 = 9900 ms.
w
Initial status for programming mode.
Maximum time between rings for an
incoming call
This consists of the time interval between two call puls-
es from the local carrier (approximately 6 seconds). At
the end of this time interval, the system disconnects
from the external line and gets ready to receive other
calls.
In some countries the pause between pulses is longer
than 6 seconds. Here you can specify the setting as you
prefer.
Required: Programming mode must be activated (*95
31994).
When the line is programmed directly, the de-
fault duration of the flash of the line is 240ms
and when the line is programmed with another
PABX system, the default duration of the flash is
100ms.
Valid only for analog trunks.