Special Class Of Service For A Blocked Extension - Siemens HiPath 1100 Programming Manual

Analog mf telephones
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Important settings
Step by step
dmj
34
Special class of service for a blocked exten-
sion
This allows you to switch a blocked extension (with an
electronic lock) to any class of service.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
w
p
Enter the extension number (e.g. 12/102).
w
p
Enter the class of service for the extension with the ac-
tivated lock:
d
= No trunk access (default setting for all exten-
sions)
e
= Outward-restricted trunk access with Denied
List 1
(10 slots)
f
= Outward-restricted trunk access with Denied
List 2
(25 slots)
g
= Outward-restricted trunk access with Denied
List 3
(35 slots)
h
= Outward-restricted trunk access with permis-
sion list 1
(10 slots)
i
= Outward-restricted trunk access with permis-
sion list 2
(25 slots)
j
= Outward-restricted trunk access with Permis-
sion list 3
(25 slots)
k
= Unrestricted trunk access (default for all lines)
w
r
Press this key.
Initial status for programming mode.
To assign a COS to additional lines, repeat the program-
ming steps described above.