Data transmission rate

The system can be connected to a PC or printer with a
V.24 adapter to display or print the ticketing report
(
page 130). The communication speed can be set to
ensure proper data transfer.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
e . m
Enter the code for the transmission (Baud) rate:
e
= 9600 Baud
f
= 14400 Baud
g
= 19200 Baud (default)
h
= 38400 Baud
i
= 56000 Baud
j
= 57600 Baud
k
= 115200 Baud
l
= 128000 Baud
m
= 256000 Baud
w
Initial status for programming mode.

25-digit suppression in CDR records

The last digits dialed in an external call can be sup-
pressed in the data output. They will be replaced by the
"?" symbol.
By default, no digit is suppressed.
Required: Programming mode must be activated (*95
31994).
w
Enter the programming code.
d . m
Select the number of digits to be suppressed.
w
Initial status for programming mode.