Setup and Installation

Technical Data

Dimensions
(Length x Depth x Height)
Weight HiPath 1150:
Maximum current:
Supply voltage:
Battery:
Type:
Connections:
Voltage:
Capacity:

Internal entrance telephone

1
Model S30817-Q930-A200
Additional components used include R1 resistance (1,2 k Ω / 0,25W / 5%),
R2 resistance (33Ω / 0,25W / 5%), and a C1 capacitor (1,0μF / 250 VAC /
non-polarized). The connection to the C.O. is made via two wires (A1 / B1)
while the connection to the entrance telephone interface is made via four
wires (A2 / B2, KL1, KL2).
228
18.50" x 14.56" x 2.83" (470 x 370 x 72
mm (1150 = 3.93"/100 mm)
8.04 lb/9.36 lb (3.65 kg/4.25 kg)
1.5 A
110 - 230 V, Full Scale, 50/60Hz
Valve-Regulated Lead Acid (VRLA)
Faston connector
27 .2V (two 12V batteries in series)
9Ah to 12Ah @ C20