Connect Cables To The Unit; Connect The Power Injector - 3Com 3CRWEASYA73 / WL-575 User Manual

Outdoor 11a building to building bridge and 11bg access point
Hide thumbs Also See for 3CRWEASYA73 / WL-575:
Table of Contents

Advertisement

C
C
ONNECT
ABLES TO THE
WARNING: Do not connect or disconnect cables or otherwise work with the
!
bridge during periods of lightning activity.
1
2
3
4
CAUTION: Be sure that grounding is available and that it meets local and national
!
electrical codes.
C
ONNECT THE
To connect the wireless bridge to a power source:
CAUTION: Do not install the power injector outdoors. The unit is for indoor
!
installation only.
U
Attach the Ethernet cable to the Ethernet port on the wireless bridge.
For extra protection against rain or moisture, apply weatherproofing tape (not
included) around the Ethernet connector.
Be sure to ground the unit with an appropriate grounding wire (not included)
by attaching it to the grounding screw on the unit.
Be sure to install a lightning arrestor on the Ethernet cable between the
bridge and power injector. The lightning arrestor should be placed outdoors,
immediately before the Ethernet cable enters the building.
Console Port
Grounding Screw
P
I
OWER
NJECTOR
NIT
PoE (Ethernet) Port
Ethernet Cable
3-7
Ground Wire

Advertisement

Table of Contents
loading

Table of Contents