Default Setting
64
Command Mode
Interface Configuration (Wireless-VAP)
Example
AP (if-wireless g: VAP[0])#max-association 32
AP (if-wireless g)#
assoc-timeout-interval
This command configures the idle time interval (when no frames are sent) after
which the client is disassociated from the VAP interface.
Syntax
assoc-timeout-interval <minutes>
minutes - The number of minutes of inactivity before disassociation.
(Range: 5-60)
Default Setting
30
Command Mode
Interface Configuration (Wireless-VAP)
Example
AP (if-wireless g: VAP[0])#association-timeout-interval 20
AP (if-wireless g: VAP[0])#
auth-timeout-value
This command configures the time interval within which clients must complete
authentication to the VAP interface.
Syntax
auth-timeout-value <minutes>
minutes - The number of minutes before re-authentication.
(Range: 5-60)
Default Setting
60