Sign In
Upload
Manuals
Brands
i-SENS Manuals
Blood Glucose Meter
CareSens N Voice
i-SENS CareSens N Voice Manuals
Manuals and User Guides for i-SENS CareSens N Voice. We have
12
i-SENS CareSens N Voice manuals available for free PDF download: Owner's Booklet, User Manual, Manual, Quick Refence Manual, Quick Reference Manual
i-SENS CareSens N Voice User Manual (48 pages)
Blood Glucose Monitoring System
Brand:
i-SENS
| Category:
Medical Equipment
| Size: 5.83 MB
Table of Contents
English
3
Table of Contents
3
Important Information: Read this First
4
Important Health-Related Information
4
Specifications
5
Caresens N Blood Glucose Monitoring System
5
Inserting or Replacing the Batteries
6
Caresens N Blood Glucose Test Strip
6
Caresens N Blood Glucose Meter
7
Caresens N Blood Glucose Meter Display
8
Setting up Your System
8
Adjusting the Date and Time
8
Setting the Sound On/Off
10
Setting the 'Test Result Reset
10
Checking the System
11
Control Solution Testing
11
Comparing the Control Solution Test Results
12
Using the Lancing Device
13
Preparing the Lancing Device
13
Preparing the Meter and Test Strip
14
Flagging Post-Meal Test Results
14
Applying the Blood Sample
15
Discarding Used Lancets
16
Alternative Site Testing
16
HI and lo Messages
18
Target Blood Glucose Ranges
18
Transferring Test Results
18
Meter Memory
19
Viewing Test Results Stored in the Meter's Memory
19
Setting the Alarm Function
20
Setting the Post-Meal Alarm (PP2 Alarm)
20
Setting the Time Alarms (Alarm 1 - 3)
20
Caring for Your System
21
Understanding Error and Other Messages
22
General Troubleshooting
23
Performance Characteristics
23
Warranty Information
25
Español
26
Informaciones Importantes: ¡Lea Esto Primero
27
Información Importante Relacionada con la Salud
27
Especificaciones
28
Sistema de Monitoreo de Glucosa Caresens N
28
Insertar O Cambiar las Pilas
29
Tiras Reactivas para Glucosa en Sangre Caresens N
29
Medidor de Glucosa en Sangre Caresens N
30
Ajustar Su Sistema
31
Ajustar la Fecha y Hora
31
Fijar el Sonido On/Off
33
Resetear Los Resultados de Los Análisis
33
Chequear el Sistema
34
Prueba con la Solución de Control
34
Comparar Los Resultados del Análisis con la Solución de Control
36
Usar el Dispositivo de Punción
36
Preparar el Dispositivo de Punción
37
Preparar el Medidor y la Tira Reactiva
38
Marcar Los Resultados de Los Análisis Después de Comer
38
Aplicar la Muestra de Sangre
38
Desechar Lancetas Usadas
39
Análisis en Lugares Alternativos
40
Mensajes HI y lo
41
Memoria del Medidor
42
Ver Los Resultados de Los Análisis en la Memoria del Medidor
42
Rangos Objetivos de Glucosa en Sangre
42
Transferir Los Resultados del Análisis
42
Ajustar la Función de Alarma
43
Fijar la Alarma para Después de Comer (Alarma PP2)
43
Fijar Alarmas de Tiempo (Alarma 1-3)
44
Cuidar Su Sistema
45
Entender el Error y Otros Mensajes
45
Solución de Problemas en General
46
Características de Funcionamiento
47
Información de Garantía
48
Advertisement
i-SENS CareSens N Voice Owner's Booklet (58 pages)
uc se Monitoring System
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 8.06 MB
Table of Contents
Table of Contents
3
Important Information: Read this First
4
Specifications
6
Caresens N POP Blood Glucose Monitoring System
7
Inserting or Replacing the Batteries
8
Caring for Your System
11
Caresens N Blood Glucose Test Strip
12
Caresens N POP Blood Glucose Meter
14
Caresens N POP Blood Glucose Meter Display
15
Setting up Your System
16
Adjusting the Date and Time
16
Setting the Sound On/Off
19
Turning on the Strip Expiration Date Indicator
20
Turning on the Hypoglycemia (Hypo) Indicator
21
Checking the System
22
Control Solution Testing
23
Comparing the Control Solution Test Results
25
Using the Lancing Device
26
Preparing the Lancing Device
27
Preparing the Meter and Test Strip
29
Flagging Post-Meal Test Results
29
Applying Blood Sample
30
Discarding Used Lancets
32
Alternate Site Testing
33
HI and lo Messages
36
Target Blood Glucose Ranges
37
Transferring Test Results
38
Meter Memory
39
Viewing Averages
39
Viewing Test Results Stored in the Meter's Memory
41
Setting the Post-Meal Alarm (PP2 Alarm)
42
Setting the Strip Expiration Date Indicator
43
Understanding Error and Other Messages
45
General Troubleshooting
47
Performance Characteristics
48
System Accuracy and Measurement Precision
48
Influence Quantities
49
User Performance Evaluation
51
Warranty Information
52
i-SENS CareSens N Voice Owner's Booklet (31 pages)
NFC
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 3.9 MB
Table of Contents
Table of Contents
3
Important Information: Read this First
4
Specifications
5
Caresens N NFC Blood Glucose Monitoring System
5
Inserting or Replacing the Battery
6
Caring for Your System
6
Caresens N Blood Glucose Test Strip
7
Caresens N NFC Blood Glucose Meter
8
Caresens N NFC Blood Glucose Meter Display
8
Setting up Your System
9
Adjusting the Date and Time
9
Setting the Sound On/Off
10
Turning on the Strip Expiration Date Indicator
11
Turning on the Hypoglycemia (Hypo) Indicator
11
Setting the Strip Expiration Date Indicator
12
Checking the System
12
Control Solution Testing
13
Comparing the Control Solution Test Results
14
Using the Lancing Device
15
Preparing the Lancing Device
15
Preparing the Meter and Test Strip
16
Applying Blood Sample
16
Discarding Used Lancets
18
Alternate Site Testing
19
HI and lo Messages
20
Target Blood Glucose Ranges
21
Transferring Test Results
21
Nfc(Near Field Communication)
21
Meter Memory
22
Viewing Averages Stored in the Memory
22
Viewing Test Results Stored in the Memory
24
Setting the Alarm Function
24
Setting the Post-Meal Alarm (PP2 Alarm)
24
Setting the Time Alarms (Alarm 1-3)
25
Understanding Error Messages
26
General Troubleshooting
27
Performance Characteristics
28
Warranty Information
30
Advertisement
i-SENS CareSens N Voice User Manual (29 pages)
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 5.01 MB
Table of Contents
Table of Contents
3
Important Information: Read this First
4
Important Health-Related Information
4
Specifications
5
Caresens N Voice Blood Glucose Monitoring System
5
Inserting or Replacing the Batteries
6
Caresens N Single Blood Glucose Test Strip
6
Caresens N Voice Blood Glucose Meter
7
Setting up Your System
8
Adjusting Language, Date, Time and Sound
8
Setting the Hypoglycemia Indicator
10
Checking the System
11
Control Solution Testing
11
Comparing the Control Solution Test Results
13
Using the Lancing Device
13
Preparing the Lancing Device
14
Preparing the Meter and Test Strip
14
Flagging Post-Meal Test Results
15
Applying the Blood Sample
15
Discarding Used Lancets
16
Alternative Site Testing
17
HI and lo Messages
18
Target Blood Glucose Ranges
19
Transferring Test Results
19
Meter Memory
19
Viewing Past Test Averages
19
Viewing Test Results
20
Setting the Alarm Function
21
Setting the Post-Meal Alarm (PP2 Alarm)
21
Setting the Time Alarms (Alarm 1 - 3)
21
Caring for Your System
22
Pre-Cleaning and Disinfection
22
Pre-Cleaning and Disinfection Procedures
23
Caution: Storage and Handling
25
Understanding Error and Other Messages
25
General Troubleshooting
27
Performance Characteristics
27
Warranty Information
29
Www.I-Sens.com
29
i-SENS CareSens N Voice Owner's Booklet (29 pages)
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 3.48 MB
Table of Contents
Table of Contents
3
Important Information: Read this First
4
Specifications
5
Caresens N Voice Blood Glucose Monitoring System
5
Inserting or Replacing Batteries
6
Caring for Your System
6
Caresens N Blood Glucose Test Strip
7
Caresens N Voice Blood Glucose Meter Display
8
Setting up Your System
9
Adjusting Date, Time and Sound
9
Setting the Hypoglycemia Indicator
11
Checking the System
12
Control Solution Testing
12
Comparing the Control Solution Test Results
14
Using the Lancing Device
14
Preparing the Lancing Device
15
Preparing the Meter and Test Strip
16
Flagging Post-Meal Test Results
16
Applying Blood Sample
17
Discarding Used Lancets
18
Alternate Site Testing
18
HI and lo Messages
20
Target Blood Glucose Ranges
20
Transferring Test Results
21
Meter Memory
21
Viewing Averages Stored in the Memory
21
Viewing Test Results
22
Setting the Alarm Function
23
Setting the Post-Meal Alarm (PP2 Alarm)
23
Setting the Time Alarms (Alarm 1-3)
23
Understanding Error Messages
24
Other Important Messages
25
General Troubleshooting
26
Performance Characteristics
26
Warranty Information
28
i-SENS CareSens N Voice Owner's Booklet (27 pages)
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 3.89 MB
Table of Contents
Table of Contents
3
Important Information:read this First
4
Specifications
5
Caresens N Blood Glucose Monitoring System
5
Inserting or Replacing the Batteries
6
Caring for Your System
6
Caresens N Blood Glucose Test Strip
7
Caresens N Blood Glucose Meter Display
8
Setting up Your System
9
Adjusting the Date and Time
9
Setting the Sound On/Off
10
Checking the System
11
Control Solution Testing
11
Comparing the Control Solution Test Results
12
Using the Lancing Device
13
Preparing the Lancing Device
13
Preparing the Meter and Test Strip
14
Marking Post-Meal Test Results
14
Applying Blood Sample
15
Discarding Used Lancets
16
Alternative Site Testing
16
HI and lo Messages
18
Target Blood Glucose Ranges
18
Transferring Test Results
19
Meter Memory
19
Viewing Averages Stored in the Meter's Memory
19
Viewing Test Results Stored in the Meter's Memory
20
Setting the Alarm Function
21
Setting the Post-Meal Alarm (PP2 Alarm)
21
Setting the Time Alarm (Alarm 1 ~ 3)
21
Understanding Error and Other Messages
22
General Troubleshooting
23
Performance Characteristics
24
Warranty Information
25
i-SENS CareSens N Voice Manual (23 pages)
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 2.79 MB
Table of Contents
Table of Contents
1
Information
2
Important Information:read this First
2
Specifications
3
Caresens N Blood Glucose Monitoring System
3
Putting in or Replacing the Batteries
4
Caring for Your System
4
Caresens N Blood Glucose Test Strip
5
Caresens N Blood Glucose Meter Display
6
Setting up Your System
7
Adjusting the Date and Time
7
Setting the Sound On/Off
8
Setting the Test Result Reset
9
Checking the System
9
Control Solution Testing
10
Comparing the Control Solution Test Results
11
Using the Lancing Device
11
Preparing the Lancing Device
12
Preparing the Meter and Test Strip
13
Marking Post-Meal Test Results
13
Applying Blood Sample
13
Discarding Used Lancets
14
Alternative Site Testing
15
HI and lo Messages
16
Target Blood Glucose Ranges
17
Transferring Test Results
17
Meter Memory
18
Setting the Alarm Function
19
Setting the Post-Meal Alarm (PP2 Alarm)
19
Setting the Time Alarm (Alarm 1 ~ 3)
19
Understanding Error and Other Messages
20
General Troubleshooting
21
Performance Characteristics
22
Warranty Information
23
i-SENS CareSens N Voice Owner's Booklet (24 pages)
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 3.67 MB
Table of Contents
Table of Contents
3
Important Information
4
Specifications
5
Caresens N Blood Glucose Monitoring System
5
Caresens N Blood Glucose Test Strip
6
Caresens N Blood Glucose Meter Display
7
Setting up Your System
8
Adjusting the Date, Time and Unit
8
Setting the Sound On/Off
9
Setting the Test Result Reset
10
Checking the System
10
Control Solution Testing
11
Comparing the Control Solution Test Results
12
Using the Lancing Device
12
Preparing the Lancing Device for Blood Sample Retrieval
13
Preparing the Meter and Test Strip
14
Flagging Post-Meal Test Results
14
Applying Blood Sample
14
Discarding Used Lancets
15
Alternative Site Testing
16
HI and lo Messages
17
Target Blood Glucose Ranges
18
Meter Memory
18
Setting the Alarm Function
19
Setting the Post-Meal Alarm (PP2 Alarm)
19
Replacing the Batteries
21
Caring for Your System
21
Understanding Error and Other Messages
22
General Troubleshooting
23
Performance Characteristics
23
Warranty Information
24
Www.I-Sens.com
24
i-SENS CareSens N Voice User Manual (26 pages)
the accuracy of the
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 2 MB
Table of Contents
Important Information: Read this First
2
Specifications
3
Caring for Your System
4
Caresens N Blood Glucose Monitoring System
5
Caresens N Blood Glucose Meter
6
Setting up Your System
7
Setting the Sound On/Off
8
Checking the System
9
Comparing the Control Solution Test Results
10
Using the Lancing Device
11
Preparing the Meter and Test Strip
12
Applying Blood Sample
13
Discarding Used Lancets
14
HI and lo Messages
16
Transferring Test Results
17
Viewing Test Results Stored in the Memory
18
Setting the Alarm Function
19
Understanding Error Messages
20
General Troubleshooting
21
Performance Characteristics
22
Warranty Information
24
i-SENS CareSens N Voice Quick Reference Manual (2 pages)
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 2.9 MB
i-SENS CareSens N Voice User Manual (2 pages)
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 1.98 MB
i-SENS CareSens N Voice Quick Refence Manual (2 pages)
Brand:
i-SENS
| Category:
Blood Glucose Meter
| Size: 3.3 MB
Advertisement
Related Products
i-SENS CareSens II
i-SENS CareSens N Pop
i-SENS CARESENS DUAL
i-SENS CareSens LINK
i-SENS CareSens N Premier
i-SENS CareSens PRO
i-SENS CareSens N Plus BT
i-SENS CareSens S Fit
i-SENS CareSens N Mini
i-SENS COOL
i-SENS Categories
Blood Glucose Meter
Measuring Instruments
Medical Equipment
Pet Care Product
Blood Pressure Monitor
More i-SENS Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL