Figure 5-71: Maintenance Actions Screen - AudioCodes Mediant 1000 User Manual

Sip media gateways
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

SIP User's Manual
To lock the gateway, take these 4 steps:
1.
Open the 'Maintenance Actions' screen (Maintenance menu).
2.
Under the 'LOCK / UNLOCK' group, from the 'Graceful Option' drop-down list, select
one of the following options:
'Yes': The gateway is 'locked' only after the user-defined time in the 'Lock
Timeout' field (refer to Step 3) expires or no more active traffic exists (the earliest
thereof). In addition, no new traffic is accepted.
'No': The gateway is 'locked' regardless of traffic. Any existing traffic is terminated
immediately.
3.
In the 'Lock Timeout' field (relevant only if the 'Graceful Option' in the previous step is
set to 'Yes'), enter the time (in seconds) after which the gateway locks. Note that if no
traffic exists and the time has not yet expired, the gateway locks.
4.
Click the LOCK button; If 'Graceful Option' is set to 'Yes', the lock is delayed and a
screen displaying the number of remaining calls and time is displayed. Otherwise, the
lock process begins immediately. The 'Current Admin State' field displays the current
state: LOCKED or UNLOCKED.
To unlock the gateway, take these 2 steps:
1.
Access the 'Maintenance Actions' screen as described above in the previous
procedure.
2.
Click the UNLOCK button. Unlock starts immediately and the gateway is ready for
new incoming calls.
Version 5.2

Figure 5-71: Maintenance Actions Screen

277