Figure 5-71: Maintenance Actions Screen - AudioCodes MP-124 User Manual

Sip cpe & access analog gateways
Hide thumbs Also See for MP-124:
Table of Contents

Advertisement

SIP User's Manual
Version 5.2
http://ArtTel.ru
To lock the gateway, take these 4 steps:
Open the 'Maintenance Actions' screen (Maintenance menu).
1.

Figure 5-71: Maintenance Actions Screen

Under the 'LOCK / UNLOCK' group, from the 'Graceful Option' drop-down list, select
2.
one of the following options:
'Yes': The gateway is 'locked' only after the user-defined time in the 'Lock
Timeout' field (refer to Step 3) expires or no more active traffic exists (the earliest
thereof). In addition, no new traffic is accepted.
'No': The gateway is 'locked' regardless of traffic. Any existing traffic is terminated
immediately.
In the 'Lock Timeout' field (relevant only if the 'Graceful Option' in the previous step is
3.
set to 'Yes'), enter the time (in seconds) after which the gateway locks. Note that if no
traffic exists and the time has not yet expired, the gateway locks.
Click the LOCK button; If 'Graceful Option' is set to 'Yes', the lock is delayed and a
4.
screen displaying the number of remaining calls and time is displayed. Otherwise, the
lock process begins immediately. The 'Current Admin State' field displays the current
state: LOCKED or UNLOCKED.
To unlock the gateway, take these 2 steps:
Access the 'Maintenance Actions' screen as described above in the previous
1.
procedure.
Click the UNLOCK button. Unlock starts immediately and the gateway is ready for
2.
new incoming calls.
237
5. Web-based Management
September 2007

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents