Canon iR2200 Service Manual page 694

Hide thumbs Also See for iR2200:
Table of Contents

Advertisement

CHAPTER 6 SELF DIAGNOSIS
E901
0000
The motor ready signal does not arrive within 1.3 sec after the pedestal
main motor drive signal is generated.
Main cause
The connector has poor connector. The pedestal main motor is faulty. The
main power supply PCB is faulty. The pedestal controller PCB is faulty.
The DC controller PCB is faulty.
Action
1. Connector
Is the wiring between the pedestal controller PCB and the main power sup-
ply PCB and between the main power supply PCB and the DC controller
PCB normal?
NO:
2. Main power supply PCB
Is the voltage between J206-2 (+) and J206-1 (-) on the main power supply
PCB about 24 V?
NO:
3. Pedestal main motor
Try replacing the pedestal main motor. Is the problem corrected?
YES: End.
4. Pedestal controller PCB, DC controller PCB
Try replacing the pedestal controller PCB. Is the problem corrected?
YES: End.
NO:
6-36 T
COPYRIGHT © 2001 CANON INC.
Correct the wiring.
Replace the main power supply PCB.
Replace the DC controller PCB.
2000 2000 2000 2000