E601
0000
When an image is transferred between the main controller PCB and the
HDD, the main controller PCB detects a fault in control information.
0001
When an image is transferred between the main controller PCB and the DC
controller PCB, the DC controller PCB detects a fault in the control infor-
mation.
Main cause
The wiring is faulty (short circuit, open circuit). The HDD is faulty. The DC
controller PCB is faulty. The main controller PCB is faulty
Action
a. E601-0000
1. Wiring
Are the connection and the cable between the connector J1017 on the main
controller PCB and the connector J1551 on the HDD normal?
YES: End.
NO:
2. HDD, Main controller PCB
Try replacing the HDD, and download the system software. Is the problem
corrected?
YES: End.
NO:
b. E601-0001
1. Wiring
Are the connection and cable between the connector J122 on the DC con-
troller PCB and the connector J1015 on the main controller PCB normal?
NO:
2. DC controller PCB, Main controller PCB
Try replacing the DC controller PCB. Is the problem corrected?
YES: End.
NO:
COPYRIGHT © 2001 CANON INC.
Correct the connection/cable.
Replace the main controller PCB.
Correct the connection/cable.
Replace the main controller PCB.