Canon iR2200 Service Manual page 687

Hide thumbs Also See for iR2200:
Table of Contents

Advertisement

E716
0000
The ID signal is not detected within a specific period of time after the pres-
ence of a pedestal is detected.
Main cause
The connector has poor connection. The main power supply PCB is faulty.
The pedestal controller PCB is faulty. The DC controller PCB is faulty.
Action
1. Connector
Is the wiring between the pedestal controller PCB and the main power sup-
ply PCB and between the main power supply PCB and the DC controller
PCB normal?
NO:
2. Main power supply PCB
Is the voltage between J206-2 (+) and J206-1 (-) on the main power supply
PCB about 24 V?
NO:
3. Pedestal controller PCB, DC controller PCB
Try replacing the pedestal controller PCB. Is the problem corrected?
YES: End.
NO:
E717
0001
The communication with the DA unit is not resumed 3 sec or more after it
is disrupted.
Main cause
The wiring is faulty (short circuit, open circuit). The DA unit PCB is faulty.
The main controller PCB is faulty.
Caution
To clear the error, execute the following in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Action
1. Connector
Is the connection between the DA unit PCB and the main controller PCB
secure?
NO:
2. DA unit PCB, main controller PCB
Try replacing the DA unit PCB. Is the problem corrected?
YES: End.
NO:
COPYRIGHT © 2001 CANON INC.
Correct the wiring.
Replace the main power supply PCB.
Replace the DC controller.
Correct the connection.
Replace the main controller PCB.
2000 2000 2000 2000
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 SELF DIAGNOSIS
6-29 T

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2800Ir3300

Table of Contents