3) Using the fixing screw [1] removed
from the dummy drum previously, se-
cure the dump unit [2] in place.
4) Fill out the date label, and attach it to
the front cover of the drum unit.
5) Turn the developing assembly locking
lever clockwise to lock the developing
assembly in place.
6) Shift up the feeding releasing lever to
lock the feeding assembly in place.
Do not turn on the main power
switch while the feeding assem-
bly remains released; otherwise,
the fixing assembly will be
damaged.
7) Close the front cover.