Flow Of Sync Signals - Canon iR2200 Service Manual

Hide thumbs Also See for iR2200:
Table of Contents

Advertisement

CHAPTER 3 LASER EXPOSURE SYSTEM

2.2 Flow of Sync signals

[1] The BD signal goes '0' when laser light is detected.
[2] The phase is matched with the phase of the printer, and a sync signal is generated.
[3] Based on the printer sync signal, image data is read from the image memory.
[4] Video signal
[5] The 2-pixel parallel signal is converted into a single-pixel serial signal.
[6] The laser drive signal is used to drive the laser unit to suit the video signal.
J3129
4
3
BD PCB
2
1
J500
Laser driver
PCB
E100
Indicates that the BD signal cannot be detected within a specific period of
time after the laser has been turned on.
3-4 P
COPYRIGHT © 2001 CANON INC.
J312
GND
B11
GND
B12
Sync signal
[1]
generation
B13
5V
B14
J307
Parallel/
[6]
serial
conversion
DC controller
PCB
F03-202-01
J316
[3]
A18
[2]
J316
[4]
[5]
2000 2000 2000 2000
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
J1015
A18
Memory
control
J1015
Controller assembly

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2800Ir3300

Table of Contents