Canon iR2200 Service Manual page 547

Hide thumbs Also See for iR2200:
Table of Contents

Advertisement

6.7.1 Main Controller PCB
J1012
J1019
J1011
J1013
J1028
J1010
The DIP switch (SW1002) is designed for adjustments at the factory, and is not normally
used in the field.
<When Replacing the PCB>
a. Transfer the following from the old to new PCB:
shorting connector of J1060
BOOT ROM of J1010
SDRAM
counter memory PCB
b. Protect the back-up data as follows:
1) Back up all data using the Service Support Tool.
2) Replace the main controller.
3) While holding down the keys '2' and '8' of the control panel, turn on the main power (to
start download mode). You will not be able to perform the following if you start up in
the usual way, since the Box text file data and control data on the hard disk will be ini-
tialized.
4) Download all data using the Service Support Tool.
COPYRIGHT © 2001 CANON INC.
CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
J1029
J1044
J1003 J1004
F04-607-01
2000 2000 2000 2000
J1022
J1060
J1024
J1061
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
J1014
J1015
J1005
J1059
J1006
SW1002
J1020
J1058
J1027
J1001
4-79 T