Detail Codes (Copier) - Canon iR2200 Service Manual

Hide thumbs Also See for iR2200:
Table of Contents

Advertisement

1.1 Detail Codes (copier)

E000
0000
The reading of the main thermistor does not reach 30°C 1 sec after the main
power switch is turned on. Or, it does not reach 70°C 2 sec thereafter.
Main cause
The fixing film unit is faulty. The main thermistor has an open circuit. The
fixing heater has an open circuit. The main power supply PCB is faulty. The
DC controller PCB is faulty.
Caution
To reset the error, execute the following in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Action
1. Connector
Is the connector of the fixing assembly connected?
a. main power supply PCB (J8) <-> relay connector <-> heater
b. DC controller PCB (J320) <-> relay connector <-> thermistor
NO:
2. Fixing film unit (thermistor)
Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of
the connectosr (4-pin) of the thermistor for electrical continuity. Is it ∞Ω
(open)?
YES: The heater has an open circuit, or the thermal switch is open. Re-
4. Main power supply PCB, DC controller PCB
Press the Start key. Is the drive voltage of the heater supplied by the con-
nector J8 of the main power supply PCB?
Main heater: between J8-1 (FSR1) and J8-5 (FSR COM)
Sub heater: between J8-3 (FSR2) and J8-5 (FSR COM)
YES: The heater drive power supply is faulty. Replace the main power
NO:
COPYRIGHT © 2001 CANON INC.
Connect the connector.
place the fixing film unit.
supply PCB.
The thermistor control mechanism is faulty. Replace the DC con-
troller PCB.
2000 2000 2000 2000
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 SELF DIAGNOSIS
6-3 T