The Copy Has Uneven Density (Darker At Front); The Copy Has Uneven Density (Lighter At Front) - Canon iR2200 Service Manual

Hide thumbs Also See for iR2200:
Table of Contents

Advertisement

CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS

3.4 The copy has uneven density (darker at front).

3.5 The copy has uneven density (lighter at front).

Developing assembly
1) Are the developing block members of the developing assembly in firm
contact with the developing assembly?
NO:
Scanner
2) Clean the scanning lamp, reflecting plate, mirrors, and lenses. Is the
problem corrected?
YES: End.
Pre-exposure lamp
3) Is the pre-exposure lamp ON during copying operation?
NO:
1.
2.
Developing assembly
4) Is the coating of toner on the developing cylinder even?
NO:
1.
2.
3.
5) Try the following modes. Is the problem corrected?
• APVC adjustment once gain in service mode: FUNCTION>DPC>D-
GAMMA.
• ATVC adjustment once again in user mode: 'roller clean' under 'adjust/
clean'.
YES: End.
Drum cartridge, Shading
6) Is there an uneven image in the halftone area of PG?
YES: Replace the drum unit.
NO:
4-12 T
COPYRIGHT © 2001 CANON INC.
Check the developing assembly locking unit.
Replace the pre-exposure lamp unit.
Replace the DC controller PCB.
Clean the tip of the blade of the developing assembly. (dry wiping)
Clean the surface of the developing cylinder.
Check the toner inside the developing assembly for uneven deposit.
Execute shading adjustment (i.e., FUNCTION>CCD>CCD-ADJ).
2000 2000 2000 2000
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2800Ir3300

Table of Contents