Providing Power To Control Modules - Notifier AM2020 User Manual

Fire alarm control panel
Hide thumbs Also See for AM2020:
Table of Contents

Advertisement

Notification appliance power can be supplied to CMX Control Modules by any one of the supplies illustrated in
Figure 4.7-2. This power is unsupervised and must be connected to a Power Supervision Relay wired to a CMX
Control Module (refer to Figures 4.7-3 through 4.7-5) or dedicated MMX module using the "MTRB" type ID.
When a remote power supply is employed, it must also be supervised.
UL Listed 24V DC Filtered
Power-limited Power Supply for use with
Fire Protective Signaling Systems
An auxiliary power supply is needed to power a CMX
notification appliance circuit when wiring losses due to long
wire runs prevent the use of the MPS-24A/E or APS-6R in
the AM2020/AFP1010 Refer to Appendix A and to the
Device Compatibility Document.
The power supply must have secondary power
source (i.e. batteries) with a backup capability equal
to the panel's backup (24 or 60 hours).
3.0 amps (filtered and power-limited)
Installation 15088: J 10/22/99
www.PDF-Zoo.com
Remote Supply
24 VDC
+ -
MPS-24A/E
Shield Drain Wire does
not connect to CMX but
should continue to the
next device
Common
-
+
+24 VDC
-
+
To next CMX or to a Power
Supervision Relay at the end of the line
(refer to Figures 4.7-3 through 4.7-5).
1-71