Type of Circuit
Main Supply Circuit
A dedicated branch of the AC
service that supplies primary AC
power to the Fire Alarm Control
Panel.
Main Supply Circuit
A dedicated branch of the AC
service that supplies primary AC
power to the Fire Alarm Control
Panel
Battery Charger Circuit
Charges and maintains the
secondary supply during non-fire
alarm conditions.
Battery Discharge Circuit
or
Secondary Power Input
Supplies power to the Fire Alarm
Control Panel during loss of
primary AC power.
Notification Appliance Power
Provides power for Notification
Appliance Circuits and remote
signaling devices.
Refer to the Device Compatibility
Document.
External Resettable Power
A-4
www.PDF-Zoo.com
Devices/Ratings
MPS-24A Main Power Supply
MPS-24B Main Power Supply
APS-6R Auxiliary Power Supply
AA-30 Audio Amplifier
AA-100/AA-120 Audio Amplifier
MPS-24AE Main Power Supply
MPS-24BE Main Power Supply
APS-6R Auxiliary Power Supply
AA-30E Audio Amplifier
AA-100E/AA-120E Audio Amplifier
MPS-24A and MPS-24E Main Power
27.6 VDC. Float type battery charger 2.0A Max. Supervised
Supplies
MPS-24B and MPS-24BE
Main Power Supplies
CHG-120 Battery Charger
3.0 amps max. draw in alarm. 25.0 amp max. screw terminal
AA-30 or AA-30E Audio Amplifier
7.3 amps max. draw in alarm. 25.0 amp max. screw terminal
AA-100/AA-120 or AA-100E/AA-120E
Audio Amplifier
6.0 amp max. draw in alarm. Battery leads are not power-
APS-6R Auxiliary Power Supply
6.0 amps max. draw in alarm. 25.0 amp max. screw terminal
MPS-24A or MPS-24AE
Main Power Supply
2.9 amps max. draw in alarm. 25.0 amp max. screw terminal
MPS-24B or MPS-24BE
Main Power Supply
MPS-24A or MPS-24AE Main Power
Supply: use with any UL listed 24 VDC
fire alarm Notification Appliance.
MPS-24B or MPS-24BE Main Power
24 VDC (2.0 amps max. of regulated current available in
Supply: use with any UL listed 24 VDC
alarm only) Power-limited and supervised with a UL listed
fire alarm Notification Appliances.
24 VDC 3.0 amps max. per circuit (6.0 amps total) in alarm
APS-6R Auxiliary Power Supply
24 VDC (200 mV ripple). 1.0 amps max. (draws from the total
standby or 6.0 amps available in alarm). Power-limited and
MPS-24A or MPS-24AE
Main Power Supply
24 VDC (200 mV ripple). 2.0 amps max. (draws from the total
standby or 6.0 amps available in alarm). Power-limited and
supervised with an A77-716 relay. Note: Optional jumper
24 VDC (200 mV ripple). 200 mA max. (draws from the total
MPS-24B or MPS-24BE
Main Power Supply
alarm. Power-limited and supervised with a UL listed relay.
Table A-2 Circuit Ratings/Connections
Circuit Ratings
120 VAC, 50/60 Hz, 1.8 amps
120 VAC, 50/60 Hz, 1.8 amps
120 VAC, 60 Hz, 2.5 amps
120 VAC, 50/60 Hz, 1.0 amps
120 VAC, 50/60 Hz, 1.85 amps
220/240 VAC, 50/60 Hz, 0.9 amps
220/240 VAC, 50/60 Hz, 0.9 amps
240 VAC, 50 Hz, 1.2 amps
220/240 VAC, 50/60 Hz, 0.5 amps
220/240 VAC, 50/60 Hz, 0.9 amps
and power-limited.
27.6 VDC. Float type battery charger (750 mA max).
Supervised and power-limited.
27.6 VDC. Float type battery charger (4.5 amps max).
Supervised and power-limited
contact rating. Supervised. Battery leads are not power-
limited.
contact rating. Supervised. Battery leads are not power-
limited.
limited.
contact rating. Supervised. Battery leads are not power-
limited.
contact rating. Supervised. Battery leads are not power-
limited.
24 VDC (3.0 amps max.) Power-limited and supervised.
relay.
only.
Power-limited and supervised with a UL listed relay.
of 3.0 amps of MPS-24A regulated current available in
supervised with an A77-716 relay.
of 3.0 amps of MPS-24A regulated current available in
selectable.
of 750 mA of regulated current available in standby and
Connections
TB1: Term. 2 + 3 (Ground)
Term 4 + 5 (Neutral)
Term 6 + 7 (Hot)
TB1: Term. 2 (Ground)
Term 3 (Neutral)
Term 4 (Hot)
TB1: Term.1 (Hot)
Term. 2 (Neutral)
Term. 3 (Ground)
Plug P2: Term. 1 + 8 (Ground)
Term 3 + 4 (Neutral)
Term 5 + 6 (Hot)
Plug P2: Term. 1 + 8 (Ground)
Term 5 + 6 (Neutral)
Term3 +4 (Hot)
TB1: Term. 2 + 3 (Ground)
Term 4 + 5 (Neutral)
Term 6 + 7 (Hot)
TB1: Term. 2 (Ground)
Term 3 (Neutral)
Term 4 (Hot)
TB1: Term.1 (Hot)
Term. 2 (Neutral)
Term. 3 (Ground)
Plug P2: Term. 1 + 8 (Ground)
Term 3 + 4 (Neutral)
Term 5 + 6 (Hot)
Plug P2: Term. 1 + 8 (Ground)
Term 5 + 6 (Neutral)
Term3 +4 (Hot)
TB2: Term. 1 (+), Term 2 (-)
TB2: Term. 5 (+), Term 6 (-)
TB2: Term. 5 (-), Term. 6 (+)
Plug P1: Term. 1 (+), Term 4 (-)
Plug P1: Term. 3 + 4 (+),
Term 1 + 2 (-)
TB3-1 (+)
TB3-2 (-)
TB2: Term. 1 (+), Term 2 (-)
TB2: Term. 5 (+), Term 6 (-)
TB3: Term. 3 (+), Term 4 (-)
TB2: Term. 3 (+), Term 4 (-)
TB2:
Output Circuit 1, 1+, 2-
Output Circuit 2, 3+,4-
TB3: Term. 1 (+), Term 2 (-)
TB3: Term. 3 (+), Term 4 (-)
TB2: Term. 1 (+), Term 2 (-)
Appendices
15088:J
10/22/99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afp1010

Table of Contents