Sign In
Upload
Manuals
Brands
Notifier Manuals
Control Panel
NFS-3030/E
Notifier NFS-3030/E Manuals
Manuals and User Guides for Notifier NFS-3030/E. We have
3
Notifier NFS-3030/E manuals available for free PDF download: Programming Manual, Operation Manual, Installation Manual
Notifier NFS-3030/E Programming Manual (144 pages)
Fire Alarm Control Panel
Brand:
Notifier
| Category:
Fire Alarms
| Size: 2 MB
Table of Contents
Table of Contents
5
Section 1 General Information
9
About this Manual
9
Supplemental Information
9
Introduction to the Control Panel
10
Features
10
Navigating Menu and Programming Screens
10
Basic Procedure
11
Getting Started
11
Password Change
11
Master Password
12
User Password
12
Incorrect or Forgotten Password
13
Section 2 Main Menu
15
Event Counts Display
15
Multiple Event List
15
History Display (History Select Screen)
15
Read Status
15
Program/Alter Status
16
Printer Functions
16
Section 3 Program
17
General Information
17
Panel Program
18
Panel Program Menu (1)
18
Network Parameters
18
Panel Settings
19
Reminder Menu
21
Panel Timers (Menu 1)
22
Panel Timers (Menu 2)
23
LCD Programming
23
ACS Programming
24
ACS Point Programming
25
Supervision
27
Panel Program Menu (2)
28
Password Change
28
Weekly Occupancy Schedule
28
Remote Display Menu
29
Remote Display Point Programming
30
Loop Configuration
30
Loop Point Programming
31
Custom Action Message
31
Event Logging
32
Holiday Menu
32
Point Program
34
Detector Point
35
Zone Map
36
Custom Action Message
37
Detector Point Programming (2)
37
Sensitivity
38
Detector Occupancy Schedule
39
Module Point
40
Module Point Programming (Monitor Module)
40
Module Point Programming (Control Module)
41
Panel Circuit Module
43
Point Programming (1)
43
Point Programming (2) - Monitor
44
General Zone
45
Point Programming (2) - Control
45
Releasing Zone
46
Releasing Zone Programming
46
Edit Logic Equation
47
Logic Zone
47
Logic Zone Programming
47
Add Logic Function
49
Add Point/ Zone
49
Add Time/Date
50
Trouble Zone
50
Trouble Zone Programming
50
Annunciator Board Label
51
Delete Program
52
Autoprogram Menu
54
To Create a New Program
54
To Add/Delete Devices from the Program
54
Confirmation Screens
55
SLC and Panel Circuit Statistics
55
Add New Points
56
Error and Discrepancy Resolution
57
Section 4 Alter Status
61
Disable/Enable Point Selection
61
Disable/Enable
62
Detector Sensitivity
62
Sensitivity Select
63
Change Alarm/Prealarm Sensitivity
63
Clear Verify Counters
64
Clear History
64
Walk Test
65
Program Time/Date
68
Control On/Off Point Select
69
Control off
69
Control on
70
Section 5 Service Screens
71
Version Information
71
Power-Up Screen
72
Bootloader Screen
72
Download Menu
73
Loop Download Menu
73
Download Screen
74
Application Corrupt Screen
75
Appendix A Menu Hierarchy
77
Screens Overview
77
Appendix B Releasing Applications
79
Releasing Zones
79
NFPA Releasing Applications
79
Abort Switches
80
ULI Abort Switch
82
IRI Abort Switch
82
NYC Abort Switch
83
Example 1 - Delay Time Does Not Exceed 120 Seconds
83
Example 2 - Delay Time Exceeds 120 Seconds
85
AHJ Abort Switch
86
Cross Zones
87
How Cross Zones Work
87
Purpose of Cross Zones
87
Using Type Codes for Releasing Zones
88
How to Program an Abort Switch
90
How to Program a Manual Release Switch
91
How to Program a Manual Release Delay Switch
92
How to Program a Second Shot Switch
94
How to Program a Release End Bell Circuit
95
How to Program a ULC Release Circuit
96
How to Program a Release Circuit
97
How to Program a Release Form-C Circuit
98
How to Program a Release Audible Circuit
99
How to Program an Instant Release Circuit
100
How to Program a Release Code Bell Circuit
101
Miscellaneous
102
Initiating Devices
102
Warning Sounders
102
Auxiliary Control Functions
102
ACS Annunciation
102
Appendix C Special Zone Outputs
103
Presignal and Positive Alarm Sequence (PAS)
103
What Is Presignal and PAS
103
Notes on Using ZF0
103
Purpose
103
Restrictions on Using ZF0
103
Selecting Presignal and PAS Outputs
104
Positive Alarm Sequence (PAS)
104
Presignal
104
Coding Functions for Panel Circuit Outputs
104
Appendix D AWACS™ Applications
105
AWACS Overview
105
AWACS Features
105
Drift Compensation and Smoothing
105
Maintenance Warnings - Three Levels
106
Self-Optimizing Pre-Alarm
107
Detector Sensitivity
107
Cooperative Multi-Detector Sensing
107
Pre-Alarm
108
Definition
108
Alert Level
108
Alert Functions
108
Action Level
109
Action Functions
109
Detector Sensitivity Settings
109
How to Select Pre-Alarm and Alarm Sensitivity
109
How to Test Detectors Set below 0.50% Obscuration Per Foot
111
Detector Status Display
111
Detector Maintenance Display
111
Print a Detector Maintenance Report
112
How to Interpret a Detector Status Display or Maintenance Report
112
Appendix E CBE: Zones and Equations
115
Zones
115
Equations
115
Arguments
116
Logic Equations
117
Logic Functions
117
The "AND" Operator
117
The "ANYX" Operator
117
The "NOT" Operator
117
The "ONLY1" Operator
117
The "OR" Operator
117
The "RANGE" Operator
117
The "XZONE" Operator
117
Time-Based Functions
117
Logic Equation Syntax Example
118
Evaluating an Equation
119
Trouble Equations
119
Appendix F Detector Initialization
121
Overview
121
How to Replace a Detector with a Different Type of Detector
121
Appendix G Type Codes
123
What Are Type Codes
123
How to Select a Type Code
123
Type Codes for Input Devices
124
Overview
124
Type Codes for Intelligent Detectors
124
Type Codes for Monitor Modules
125
Type Codes for Output Devices
126
Flashscan Codes
127
Appendix H System Troubles
129
Section 6 Glossary
131
Advertisement
Notifier NFS-3030/E Operation Manual (72 pages)
Fire alarm control panel
Brand:
Notifier
| Category:
Control Panel
| Size: 1 MB
Table of Contents
Table of Contents
5
Installation Precautions
3
Section 1 General Information
7
About this Manual
7
Supplemental Information
7
Introduction to the Control Panel
8
Operating Features
8
The Display/Keypad
9
The Keypad
9
The Liquid Crystal Display
9
Fixed Function Keys
10
Keypad
10
Soft Keys
10
Special Function Keys
10
LED Indicators
11
Message Formats
11
System Normal Screen
11
Event Reporting Format
12
Point Events Format
12
Figure 1.3 Point Event Display Example
13
System Events Format
13
Navigating Menu and Programming Screens
14
The Main Menu
14
Event Counts Display
15
F I R E a L a R M E L E V a T O R L O B B y E a S T W I N G F I F T H F L O O R
15
More Information
16
S M O K E ( P H O T O )
16
Multiple Event List
17
History Display (History Select Screen)
18
1 : 5 8 : 4 5 a W E D J U
18
E a S T W I N G F I F T H F L O O R
18
S M O K E ( P H O T O )
18
Read Status
19
Program/Alter Status
19
Printer Functions
19
Section 2 Operation of the Control Panel
20
Overview
20
Acknowledging an Event
20
System Normal
20
Fire Alarm Event
22
E V E N T C O U N T S
22
How the Control Panel Indicates a Fire Alarm
22
How to Respond to a Fire Alarm
22
A C K N O W L E D G E S I G N a L S I L E N C E
22
M O R E I N F O R M a T I O N S y S T E M R E S E T
22
1 : 5 8 : 4 5 a W E D J U
22
Interpreting Type ID Codes
23
System or Point Trouble Event/How the Control Panel Indicates a System or Point Trouble
24
System or Point Trouble Event
24
How the Control Panel Indicates a System or Point Trouble
24
How to Respond to a System or Point Trouble
25
Point (Device) Troubles
25
Point Troubles Table
25
Trouble Types
25
System Troubles
26
Interpreting Type ID Codes
27
1 : 5 8 : 4 5 a W E D J U
28
Interpreting Type ID Codes
29
Pre-Alarm Event
28
How the Control Panel Indicates a Pre-Alarm
28
How to Respond to a Pre-Alarm Warning
28
1 : 5 8 : 4 5 a W E D J U
30
1 : 5 9 : 3 5 a W E D J U
30
Interpreting Security Type Codes
31
Security Alarm Event
30
E V E N T C O U N T S F I R E a L a R M S : 0 0 0 P R E a L a R M : 0 0 0 T R O U B L
30
How the Control Panel Indicates a Security Alarm
30
How to Respond to a Security Alarm
30
Supervisory Signal Event
32
How the Control Panel Indicates an Active Supervisory
32
How to Respond to an Active Supervisory
32
How to Interpret Type Codes
33
Disabled Points Event
34
Active Event
35
How the Control Panel Indicates an Active Fire Control Point
35
How the Control Panel Indicates an Active Non-Fire Point
35
Special System Timers/Presignal/Pas
36
Operation of Special System Timers, Presignal, and PAS
36
AC Fail Delay Timer
36
Alarm Verification Timer (VERIFY TIME)
36
Auto Silence Timer
36
Presignal
36
Silence Inhibit Timer
36
System (Panel) Timers
36
How the Panel Indicates a Presignal Alarm
37
How to Respond to a Presignal Alarm
37
PAS (Positive Alarm Sequence)
37
Section 3 Read Status
38
Point Select Screen
38
Smoke Detector
39
Heat Detector
40
Monitor Module
41
Control Module
41
Panel Input
43
Panel Output
43
General Zone
44
Logic Zone
44
Releasing Zone
45
Special Function Zone
45
Trouble Zone
46
Annunciator
46
Section 4 Viewing and Printing History Information
48
Events History
48
Time and Date Range Selection for All Events
49
Point Range Select for All Events in Range
50
Section 5 Printing Reports
51
Printer Functions Screen
51
Print Programming Menu Screen
52
Print Programming Menu Screen (2)
54
Active Points Report Screen
55
Installed Points Report Screen
55
Appendix A Software Type ID Codes
59
Appendix B Releasing Zones
61
Limited Warranty
71
Notifier NFS-3030/E Installation Manual (68 pages)
fire alarm Control Panel
Brand:
Notifier
| Category:
Control Panel
| Size: 2 MB
Table of Contents
Installation Manual
1
Installation Precautions
3
Fcc Warning
3
Table of Contents
5
Section 1 about this Manual
7
Standards and Other Documents
7
Supplemental Documentation
8
Cautions and Warnings
9
Section 2 System Overview
10
System Description
10
Standard Features
10
Options
10
System Limitations
10
System Components
11
Product Diagram
11
Main Power Supply
13
System Cabinets
14
Compatible Equipment
15
System Sensor Compatible Equipment
16
Section 3 Installation
17
Preparing for Installation
17
Installation Checklist
17
Mounting a Cabinet
19
Laying out Equipment in Cabinet and Chassis
20
Attaching the CPU & Chassis
21
Memory-Backup Battery
22
Attaching Option Boards
22
Attaching Panel Circuit Modules
23
Overview
23
Mount Expander Boards
24
Installing a Multi-Layer Module into the Chassis
25
Connecting Expander Row Ribbon Cables
26
Initiating Device Circuits with IZM-8RK/IZE-A
27
Style B Field Wiring
27
Style D Field Wiring
28
Nacs with ICM-4RK⁄ICE-4
29
Power Supply Connections
30
Form-C Relays on the CPU
31
Form-C Relays with CRM-4RK/CRE-4
32
Form-C Relays with Auxiliary Relay Module (ARM-4)
33
Overview
33
Installation
33
Field Wiring an Auxiliary Relay Module
34
Notification Appliance Circuit Current Limitations
35
Connecting Specific Option Boards
36
Network Control Module
36
Loop Control Module, Loop Expander Module
36
Lcm-320 & Lem-320 Connecting Diagram
37
Connecting Power Sources and Outputs
39
Overview
39
Connecting the Power Supply
39
Checking AC Power
40
Auxiliary Power Supply Connections
40
UL Power-Limited Wiring Requirements
41
ULC Remote Connection Feature
41
Installing Printers
42
Printer Installation Sequence
42
Configuring the Printer
44
Wiring a Signaling Line Circuit (SLC)
45
Overview
45
Capacity
45
Installation
45
Connecting a PC for Programming
46
Section 4 Applications
47
Overview
47
Devices Requiring External Power Supervision
47
NFPA 72 Central or Remote Station Fire Alarm System (Protected Premises Unit)
48
NFPA 72 Proprietary Fire Alarm Systems
49
Fire/Security Applications
50
General Operation
50
General Security Requirements
50
Installing a Security Tamper Switch
51
Receiving Unit
51
Programming
51
Wiring for Proprietary Security Alarm Applications
52
Connecting an RKS-S Remote Key Switch
53
Single Tenant Security System with Entry/Exit Delay
54
Programming Notes for Figure
55
Security Annunciation
56
Releasing Applications
57
Connecting a Releasing Device to a FCM-1 Module
58
Connecting an NBG-12LRA Agent Release-Abort Station
58
Section 5 Testing the System
60
Acceptance Test
60
Periodic Testing and Service
60
Operational Checks
60
Battery Checks and Maintenance
61
Appendix A Electrical Specifications
62
Operating Power
62
SLC Loops
62
Notification Appliance Circuits
62
Wire Requirements
63
Appendix B Canadian Applications
64
Standalone Application
64
Local Network Application
64
Automatic Alarm Signal Silence
64
Annunciator Applications
64
Releasing Devices
64
Limited Warranty
67
Advertisement
Advertisement
Related Products
Notifier NFS-320
Notifier NFS-320SYS
Notifier NFS-320SYSE
Notifier NFS-320E
Notifier NFS-320C
Notifier NFS-3030
Notifier NFS-E
Notifier NFS2-640/E
Notifier NFS2-3030/E
Notifier NFS2-3030
Notifier Categories
Fire Alarms
Control Panel
Smoke Alarm
Control Unit
Security System
More Notifier Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL