Notifier Inertia 1010 Operator's Manual
Notifier Inertia 1010 Operator's Manual

Notifier Inertia 1010 Operator's Manual

Intelligent fire detection and alarm system
Hide thumbs Also See for Inertia 1010:

Advertisement

Quick Links

NSW (Head Office)
7 Columbia Court
Norwest Business Park
Baulkham Hills NSW 2153
Ph:
(02) 9899-4155
Fax:
(02) 9899-4156
Notifier Inertia Pty Ltd (A.C.N 002 692 962)
A PITTWAY COMPANY
A PITTWAY COMPANY
www.inertia.com.au
O
PERATORS
QLD
16 Lucy St
Moorooka
Qld 4104
Ph:
(07) 3892-6444
Fax:
(07) 3892-6455
M
1010
2020
I
NTELLIGENT
D
ETECTION AND
A
LARM
S
OFTWARE
R
EVISION
VIC
Unit 2 297 Ingles St
Port Melbourne
Vic 3207
Ph:
Fax:
ANUAL
F
IRE
S
YSTEM
V
3.0
ERSION
AUS1
(03) 9681-9929
(03) 9681-9930

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Inertia 1010 and is the answer not in the manual?

Questions and answers

Summary of Contents for Notifier Inertia 1010

  • Page 1 Port Melbourne Baulkham Hills NSW 2153 Qld 4104 Vic 3207 (02) 9899-4155 (07) 3892-6444 (03) 9681-9929 Fax: (02) 9899-4156 Fax: (07) 3892-6455 Fax: (03) 9681-9930 Notifier Inertia Pty Ltd (A.C.N 002 692 962) A PITTWAY COMPANY A PITTWAY COMPANY www.inertia.com.au...
  • Page 2: Table Of Contents

    1010/2020 O PERATORS ANUAL ABLE ONTENTS TABLE OF CONTENTS............................2 BASIC OPERATIONAL PROCEDURES......................3 : ..............................3 CKNOWLEDGE ILENCE LARMS ................................3 ILENCE XTERNAL ..................................3 CKNOWLEDGE AULTS ............................3 SOLATE EVICE URRENTLY LARM ..................................... 3 ESET ANEL ................................3 ESET ONDITIONING ..............................
  • Page 3: Basic Operational Procedures

    1010/2020 O PERATORS ANUAL ASIC PERATIONAL ROCEDURES CKNOWLEDGE ILENCE LARMS Press To individually acknowledge alarms. The fire alarm LED will go steady and the buzzer will silence once alarms have been acknowledged. NEXT ILENCE XTERNAL Press To isolate (silence) the external bells. The yellow LED labeled "EXT BELL ISOLATED"...
  • Page 4: Solatea Detector Odule

    1010/2020 O PERATORS ANUAL (CONT) ASIC PERATIONAL ROCEDURES SOLATE ETECTOR ODULE EG: Loop 1 Detector 26 Press ALTER ENTER > > STATUS Enter* Press L1D26 ENTER The LCD will then ask, "Do you want this point isolated? [Y = YES N = NO] " Enter* Press ENTER...
  • Page 5: The Keyboard

    1010/2020 O PERATORS ANUAL EYBOARD © 2000, N OPYRIGHT OTIFIER NERTIA...
  • Page 6: System Overview

    The 1010 panel is capable of 4 loops and the 2020 is capable of 10 loops. Each or these panels may then be networked together on our customised network protocol known as Notifier-Net which provides peer to peer or master slave networking allowing may thousands of detectors and Input/Output (I/O) points to be monitored and controlled.
  • Page 7: Lcd Displays Explained

    1010/2020 O PERATORS ANUAL LCD D ISPLAYS XPLAINED LL SYSTEMS ORMAL ISPLAY When the system is in normal mode (ie: No faults, alarms or isolates) it will display the "ALL SYSTEMS NORMAL" message. The insert “building name here” is a 20 character area, which can be customised. INSERT BUILDING NAME HERE ALL SYSTEMS NORMAL 13:20...
  • Page 8: Operating The Panel

    1010/2020 O PERATORS ANUAL PERATING ANEL CKNOWLEDGING Each and every alarm event that takes place on the system is required to be individually Acknowledged. This acknowledgment process confirms to the system that an operator is aware of the situation and as such the internal buzzers no longer require sounding.
  • Page 9: Operating Annunciators

    LCD-80 The Notifier LCD-80 Mimic is a remote LCD mimic which has a 4 x 20 LCD displaying text messages as per the main system LCD. From this point you can acknowledge, scroll and reset the panel as per the main panel control.
  • Page 10: Read Status Menu

    1010/2020 O PERATORS ANUAL TATUS The READ STATUS menu provides the following options: Selection Abbreviation Description YSTEM TATUS Provides information on currently programmed System Parameters. Refer programming manual for details. PTREAD OINT Provides an instant "snap shot" of the current status of any device in the system, including obscuration levels, verification count, options etc.
  • Page 11: Alter Status Menu

    1010/2020 O PERATORS ANUAL LTER TATUS MENU The ALTER STATUS menu provides the following options: Selection Abbreviation Description SOLATE UNCTION Provided the ability to isolate / de-isolate individual points on the system. Enter the detector, module or zone number and then select Y to isolate or N to de-isolate.
  • Page 12: System Test Menu

    1010/2020 O PERATORS ANUAL During a walk test, as each detector alarms it will not display on the LCD, it’s LED will activate for 5 seconds and outputs set as “Walk Test” will toggle on for 10 seconds then reset. These outputs should be connected to sounders or bells to confirm to the testing technician that the alarm has been received at the panel.
  • Page 13: System History Event Log

    1010/2020 O PERATORS ANUAL YSTEM ISTORY VENT The panel has the option to store a history buffer of the last 400 events on the system. These events can then be displayed or printed in event order or grouped in reports. If this feature has been enabled, it can be accessed as follows.
  • Page 14: T O Clear The History Log

    1010/2020 O PERATORS ANUAL 1= PRINT, Print history log directly to system printer. 2= DISPLAY, Displays the History log on the LCD and scrolls automatically 3= STEP, Displays the history log on the LCD and scrolls one event each time the "ENTER"...
  • Page 15: How To Set The Date And Time

    1010/2020 O PERATORS ANUAL OW TO SET THE ATE AND Enter Alter Status menu by pressing ALTER STATUS Select 4=TIME You will then be prompted to enter the following Valid Reponses Enter the month (1-12) Enter the day of month (1-31) Enter the year (0-99)