Type Codes For Output Devices; Overview; Type Codes For Control Modules - Notifier NFS-640 Programming Manual

Fire alarm control panel
Hide thumbs Also See for NFS-640:
Table of Contents

Advertisement

Appendix F: Type Codes

Type Codes for Output Devices

Overview

This section provides Type Codes for control modules, NACs, and Panel Circuits. For instructions on
programming Type Codes, refer to "How to Modify or Delete a Point (2=point)" on page 21.

Type Codes for Control Modules

A comprehensive list of control module Type Codes, which you can select to change the function of an
control module point.
Silenceable
Type Code
CONTROL
RELAY
BELL CIRCUIT
STROBE CKT
HORN CIRCUIT
AUDIBLE CKT
SPEAKER
ISOLATED NAC
ISOLATED SPK
REL END BELL
blank
REL CKT ULC
RELEASE CKT
RELEA.FORM C
REL AUDIBLE
NONRESET CTL
TELEPHONE
INSTANT RELE
ALARMS PEND.
CONTROL NAC
GEN ALARM
GEN SUPERVIS
GEN TROUBLE
GENERAL PEND
TROUBLE PEND
106
www.PDF-Zoo.com
Configuration
(Y/N)
Y
NAC
Y
Form-C relay
Y
NAC
Y
NAC
Y
NAC
Y
NAC
Y
NAC
Y
NAC
Y
NAC
N
NAC
Y
NAC
N
NAC
N
NAC
N
Form-C Relay
Y
NAC
N
Form-C Relay and NAC
N
NAC
N
NAC
N
NAC
Y
NAC
N
NAC
N
NAC
N
NAC
N
NAC
N
NAC
Table 34 Control Module Type Codes
Device Function
Supervised NAC for notification appliance
Relay output
Supervised NAC for notification appliance
Supervised NAC for notification appliance
Supervised NAC for notification appliance
Supervised NAC for notification appliance
Supervised NAC for notification appliance
Supervised NAC for notification appliance, used with audio isolators. Activates
even if there is a short on its NAC circuit. For ULC installations only.
Supervised NAC for speaker circuits, used with audio isolators. Activates even if
there is a short on its audio circuit. For ULC installations only.
Supervised NAC for notification appliance
Supervised NAC (for use when no other Type Code applies)
Releasing Circuit, power-limited, supervised for opens, shorts and ground faults
(always non-silenceable)
Releasing circuit, nonpower-limited, supervised for opens and ground faults
Relay output, contacts operate upon release
NAC, activated upon release
Relay output, unaffected by "System Reset" command
Standard Telephone circuit
NAC, short = normal; supervised for open circuits and ground faults. Always non-
silenceable and switch-inhibited.
Output that will activate upon receipt of an alarm condition, and remain in the
alarm state until all alarms have been acknowledged. It is programmed as "switch
inhibit".
Supervised NAC
Control Module, an XPC-8 circuit, or an
Municipal Box Transmitter for NFPA 72-1999 Auxiliary Fire Alarm Systems
applications. This Type ID can also be used for general alarm activation. It is
programmed as "switch inhibit".
Control Module, an XPR-8 relay, or an
Supervisory condition (includes sprinkler type). It is programmed as "switch inhibit".
Control Module, an XPR-8 relay, or an
System Trouble condition. It is programmed as "switch inhibit".
Control Module, an XPC-8 circuit, or an
upon receipt of an alarm and/or trouble condition, and remain in the ON state until
all events have been ACKNOWLEDGED.
Control Module, an XPC-8 circuit, or an
upon receipt of a trouble condition, and remain in the ON state until all troubles
have been ACKNOWLEDGED. It is programmed as "switch inhibit".
NFS-640 Programming Manual P/N 51333:B 10/03/2003
Type Codes for Output Devices
XP5-C
(in NAC mode) configured as a
XP5-C
(in relay mode) activated under any
XP5-C
(in relay mode) activated under any
XP5-C
(in NAC mode) that will activate
XP5-C
(in NAC mode) that will activate

Advertisement

Table of Contents
loading

Table of Contents