Multiple Tenant Security System With Entry/Exit Delay - Notifier AM2020 User Manual

Fire alarm control panel
Hide thumbs Also See for AM2020:
Table of Contents

Advertisement

The following system requirements are illustrated in Figure 1.3-9. See Table 1.1-1 in the introduction to this
section for monitor and control module options.
• One AM2020/AFP1010 Control Panel
• Multiple Security Supervisory Circuits Reporting to Central Station as a Single Area
• Multiple Protected Premises, each with System Arm/Disarm Capability and Central Station Ringback Signal
• The minimum security equipment required is as follows:
— Multiple MM Monitor Modules per Protected Area
— One Group Interface per Grouped Area
— Contact Switch for Each Entry/Exit Door
— RKS-S Keyswitch
— MM Monitor Modules
— ACM-16AT or ACM-32A Remote Annunciator for Each Entry/Exit Door
— Security Devices
Figure 1.3-9 Multiple Tenant Security System with Entry/Exit Delay
Zone Programming Notes for Figure 1.3-9
MM Security Access Monitor
Provide a unique annunciator point for each Security Access Monitor installed.
Notification Appliance w/CM Module
When using an optional control module for Notification Appliances intended to indicate a security violation, the
control module intended for Tenant A may be programmed with the following Control-By-Event equation:
and Tenant B may be programmed with the following Control-By-Event equation:
resulting in 15 minutes of Notification Appliance activation after a security violation.
Program Tenant A using zone numbers Zaa through Zaj as in Figure 1-6. Program Tenant B as in Figure 1-6, but substitute
Zba through Zbj for Zaa through Zaj respectively. *Zaa through Zaj are each unique installer-specified zone numbers. Zaa is the
lowest specified zone number (highest priority) and Zaj is the highest specified zone number (lowest priority).
Example:
ï
Security 15088:J
10/22/99
www.PDF-Zoo.com
TENANT A
AREA 1
(Perimeter
and
Interior)
AREA 1
(Perimeter
and
Interior)
TENANT B
AND(Zab* SDEL(00.00.00 00.15.00 (Zaj*)))
AND(Zbb* SDEL(00.00.00 00.15.00 (Zbj*)))
Zone Boundary greater than or equal to Z22 and less than Z100.
Zaa
Zab
Zac
Zad
Z5
Z12
Z22
Z180
Zba
Zbb
Zbc
Zbd
Z6
Z7
Z21
Z100
ð
Forward Zones
MM CM
*
MM CM
Signaling
Line
Circuit
*
MM CM
Zae
Zaf
Zag
Z188
Z199
Z200
Zbe
Zbf
Zbg
Z102
Z108
Z187
ï
Reverse Zones
Key
Motion Detector
Contact Switch
Contact Switch w/MM
RKS-S Remote Keyswitch w/MM
MM Security Area Monitor
ACM-16AT or ACM-32A Remote Annunciator
*
Group Interface
*
Group Interface
Shaded Area Indicates
must be physically
Second Tenant
located in either the
protected premises or
Pull Station
the Central Station
Smoke Detector
AM2020/AFP1010
Central Station
Zah
Zai
Zaj
Z210
Z211
Z212
Zbh
Zbi
Zbj
Z191
Z193
Z215
ð
4-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afp1010

Table of Contents