Troubleshooting automation
System Type
Automation
Automation
Automation
Automation
Automation
Automation
Automation
Automation
Automation
Automation
Error description messages
The following table contains the possible error description messages for both the file
and automation systems, which will start on the second line of the error message. The
"Error Message" column in the table contains the error message text that immediately
follows the "response:" text. For ease of reference the table lists the error messages in
alphabetical order.
Table 15: List of error description messages
Error Message
hexadecimal
number
<error code in
hexadecimal>
unknown error
code
a
artefact clone
policy violation
PRO2 Live Audio System
Owner's Manual
Error Message
Failed to insert point scene
Failed to load show
Failed to recall last scene
Failed to recall Next scene
Failed to recall Now scene
Failed to rename point scene
Failed to save file
Failed to save file to new
name
Failed to store point scene
Failed to unexpand point
scene range
System(s)
Problem
File and
Indication of a possible
Automation
system error.
File and
The cloning of this artefact
Automation
(file type) is not allowed.
Fault Condition
Attempting to complete point scene
storage by clicking OK after
selecting "Insert before scene".
Attempting to load a show file.
Attempting to recall the previous
scene to the control surface.
Attempting to recall the next scene
to the control surface.
Attempting to reload the current
scene or the current jog scene (if
any) to the control surface.
Attempting to rename a point scene.
Attempting to save a currently
loaded file.
Attempting to save a currently
loaded show file to another file
name, that is, by using the Save As
button.
Attempting to complete point scene
storage by clicking OK after
selecting "Store to empty scene",
"Overwrite scene" or "Store to
empty scene".
Attempting to unexpand point scene
range. This is the opposite of
expanding the point scene range
(immediately above) and can only
be carried out if the 10 point scenes
to be unexpanded are empty.
Solution
Note down the hexadecimal
value of the error code and
contact Midas Technical
Support, giving them this
value.
Avoid using this type of
operation.