Charging System Repair Procedupes - TOHATSU NB-1000 Service Manual

2 stroke 1&2 cylinder models
Table of Contents

Advertisement

SECTION 7
5
Continuity on chart means that the meter showed
continuity (some resistance indicated by meter -
exact value depends on test conditions). No
Continuity on chart means that meter had no
deflection.
Terminal
BLACK
Terminal
Teste
Lead
Terminal
Terminal
5. Connect rectifier/regulator leads.

Charging System Repair Procedupes

5
Disable ignition system, by disconnecting exciter
coil terminals (4), (5), (6), (7), to prevent accidental
engine startup during removal and replacement
of the flywheel.
7-72
NOTE
2
Terminal
2
NA
NO Continuity
3
NO Continuity
4
NO Continuity
5
WARNING
T1797
RED Tester Lead
3
Terminal
Terminal
Continuity
Continuity
NA
NO Continuity
NO Continuity
NO Continuity
4
Terminal
Continuity
Continuity
NA
Continuity
NA
NA
1-/ 2-Cylinder
5