SECTION 7
If the meter does not indicate continuity, clean connections and/or
replace negative battery cable.
If the meter indicates continuity, go to the next step.
3. Set analog multimeter to "iDCV" and set range to "20". Connect
BLACK tester lead to "- COM" and the RED tester lead to "+ VΩ".
4. Connect BLACK tester lead to clean engine ground.
5. Connect RED tester lead to positive battery terminal (4).
If meter does not indicate 11.8 to 13.2 VDC (battery voltage), see
Battery Care and Maintenance, this section.
If meter indicates battery voltage go to next step.
6. Reconnect negative battery cable (3) to negative battery terminal
(1).
7. Connect RED tester lead to starter solenoid terminal (5).
If meter does not indicate battery voltage, replace battery cable (6).
If meter indicates battery voltage go to next step.
8. Disconnect lead (7) from starter solenoid (8) to starter motor (9).
9. Connect RED tester lead to starter solenoid lead (7) and turn
main key switch (10) to START position.
If meter indicates battery voltage, repair or replace starter motor,
see Starter Motor Tests in this section.
If meter does not indicate battery voltage, go to next step.
10. Connect RED tester lead to connector closest to fuse holder (11).
If meter does not indicate battery voltage, repair or replace cable
between (5) and (11).
If meter indicates battery voltage, go to next step.
7-54