SECTION 7
3. The meter should indicate the following resistance for pulser coils:
Engine Models
2.5 / 3.5
5
8 / 9.8
9.9D / 15D / 18E
9.9D
/ 15D
/ 18E
2
2
25C
/ 30A
2
3
25C
/ 30A
3
4
40
40
4. If the resistance is not within the indicated range, replace the
pulser coil. See Ignition System Repair Procedures - Pulser Coil.
After repairs are made, return to Ignition System Performance
Testing Flow Chart.
If the resistance is within the indicated range, proceed to the next
step.
5. Set the analog multimeter to "20" on the "DVA" scale.
6. Insert the banana plug of the RED tester lead into the meter
connection labeled "DVA" and the banana plug of the BLACK tester
lead into the meter connection labeled "-COM".
7-34
Results
N/A
80 - 117 Ω ± 25%
N/A
30 - 46 Ω ± 25%
N/A
2
30 - 46 Ω ± 25%
N/A
30 - 46 Ω ± 25%
N/A
1-/ 2-Cylinder