Epson Stylus Pro 7710 Service Manual page 297

Large format color inkjet printer
Hide thumbs Also See for Stylus Pro 7710:
Table of Contents

Advertisement

Epson Stylus Pro 7700/7710/7900/7910/9700/9710/9900/9910
12. Select
Mecha Adjustment
Temporary
13. Press
[OK]
while
[Enter] Un Cap
The carriage unit will be unlocked.
This step is not necessary for Epson Stylus Pro 7900/7910.
14. Open the Front Cover (Middle).
15. Move the Carriage Unit to the belt tension measuring position manually.
Epson Stylus Pro 9900/9910: Position as shown in the
Epson Stylus Pro 7900/7910: Home position (Carriage is locked.).
Mark
Align the mark on the
left of the Carriage
Unit with the one on
the Main Frame.
Carriage Unit
Figure 5-14. Belt Tension Measuring Position
ADJUSTMENT
PG.
is displayed.
Figure 5-14
below.
CR Related Adjustment
16. Input the following values to the tension meter.
WEIGHT:
1.0
WIDTH:
008.0
SPAN:
1170
17. Bring the microphone of the Sonic Tension Meter U-505 closer to the center of the
Timing Belt on the rear side.
Be sure to measure the tension of the belt on the rear side. If you
C A U T I O N
measure the tension of the belt on the front side, the measuring
value may be inaccurate.
Bring the microphone within 5mm from the Timing Belt but do not
C H E C K
P O I N T
let it touch the belt.
18. Press [MEASURE] on the Sonic Tension Meter U-505 and flip the Timing Belt
with tweezers or a similar tool.
Flip the Timing Belt as weak as the Sonic Tension Meter U-505
C A U T I O N
can measure it.
Be careful not to let the microphone touch the Timing Belt
when flipping the belt.
Within the standard value: Close the Front Cover (Middle) and press
while
[Enter] Cap
is displayed to cap the printhead. After the printhead is
secured, turn the printer OFF and finish the adjustment.
Out of the range:
Go to
Revision D
[OK]
Step
19.
298

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stylus pro 9900Stylus pro 7900

Table of Contents