4.
Hold up the Pressurizing Unit, and release the harness from the clamp and the
cable retainer.
5.
Disconnect the two connectors, and remove the Pressurizing Unit.
Be sure to refer to Chapter 5 "Adjustment"
A D J U S T M E N T
R E Q U I R E D
specified adjustments after replacing the Pressurizing Unit.
<Adjustment Item>
1.
Counter Clear (Pressure Motor)
DISASSEMBLY & ASSEMBLY
(see p283)
and perform
Disassembly and Assembly Procedure
M
Pressurizing Unit
Connector
Cable retainer
Connector
Clamp
Figure 4-121. Removing the Pressurizing Unit
Revision D
215