4.4.5.5 Rewind Unit
The Rewind Unit is established as an ASP including the mounting
C A U T I O N
plate. When replacing this part, transfer the necessary items or
replace the whole unit.
1.
Remove the Control Panel.
(p142)
2.
Remove the IC Cover R and the IC Shaft Cover R.
3.
Remove the Maintenance Tank R.
4.
Remove the Right Cover.
(p148)
5.
Remove the Spindle Cover R.
(p154)
6.
Release the harness from the clamp, and disconnect the connector from the
Rewind Unit.
7.
Remove the three screws that secure the Rewind Unit Mounting Plate, and remove
the Rewind Unit Mounting Plate.
A) Silver, Phillips, Bind machine screw M3x6: three pieces
8.
Remove the two gears from the Rewind Unit Mounting Plate.
DISASSEMBLY & ASSEMBLY
(p145)
(p147)
Disassembly and Assembly Procedure
- Right side -
Rewind Unit
Connector
Rewind Unit Mounting Plate
Figure 4-87. Removing the Rewind Unit Mounting Plate
Gear
Figure 4-88. Removing the gears
Revision D
A
Clamp
Rewind Unit Mounting Plate
Gear